Evidence map›Paper›PMID 28812002›Full record

ReviewQuantitative imaging in medicine and surgery2017

Image-guided thermal ablation with MR-based thermometry.

Mingming Zhu, Ziqi Sun, Chin K Ng

Abstract readReview
In one paragraph

Review in Quantitative imaging in medicine and surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Tissue Ablation: Applications and Perspectives.Advanced materials (Deerfield Beach, Fla.) · 2024
    Review
  5. Review
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Predicting brain temperature in humans using bioheat models: Progress and outlook.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2023
    Review
  14. Article
  15. Review
  16. Article
  17. One-Step Preparation of Highly Stable Copper-Zinc Ferrite Nanoparticles in Water Suitable for MRI Thermometry.Chemistry of materials : a publication of the American Chemical Society · 2022
    Article
  18. Phase-independent thermometry by Z-spectrum MR imaging.Magnetic resonance in medicine · 2022
    Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mingming ZhuDepartment of Radiology, School of Medicine, University of Louisville, Louisville, KY, USA.
Ziqi SunDepartment of Radiology, School of Medicine, University of Louisville, Louisville, KY, USA.
Chin K NgDepartment of Radiology, School of Medicine, University of Louisville, Louisville, KY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Thermal ablation techniques such as radiofrequency, microwave, high intensity focused ultrasound (HIFU) and laser have been used as minimally invasive strategies for the treatment of variety of cancers. MR thermometry methods are readily available for monitoring thermal distribution and deposition in real time, leading to decrease of incidents of normal tissue damage around targeted lesion. HIFU and laser-induced thermal therapy (LITT) are the two widely accepted tumor ablation techniques because of their compatibility with MR systems. MRI provides multiple temperature dependent parameters for thermal imaging, such as signal intensity, T1, T2, diffusion coefficient, magnetization transfer, proton resonance frequency shift (PRFS, including phase imaging and spectroscopy) as well as frequency shift of temperature sensitive contrast agents. Absolute temperature mapping techniques, including both spectroscopic imaging using metabolites as a reference and phase imaging using fat as a reference, are immune to susceptibility effects and are not dependent on phase differences. These techniques are intrinsically more reliable than relative temperature measurement by phase mapping methods. If the limitation of low temporal and spatial resolution could be overcome, these methods may be preferred for MR-guided thermal ablation systems. As of today, the most popular MR thermal imaging method applied in tumor thermal ablation surgery is, however, still PRFS based phase mapping technique, which only provides relative temperature change and is prone to motion artifacts.

Indexed as

high intensity focused ultrasound (HIFU)laser induced thermal therapy (LITT)MR guided thermal ablationMR thermometrythermal dosimetrytumor thermal ablation

Identifiers

PMID28812002
PMCPMC5537124

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.