Evidence map›Paper›PMID 28808925›Full record

GuidelineClinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico2018

Recommendations of the Spanish brachytherapy group (GEB) of Spanish Society of Radiation Oncology (SEOR) and the Spanish Society of Medical Physics (SEFM) for high-dose rate (HDR) non melanoma skin cancer brachytherapy.

S Rodríguez, M Arenas, C Gutierrez, J Richart, J Perez-Calatayud, F Celada, M Santos, A Rovirosa

Abstract readConsensus StatementPractice Guideline
PubMed Publisher
In one paragraph

Guideline in Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. High-dose-rate plesiotherapy with customized molds in non-melanoma skin cancer: efficacy and safety at 10 years-single institution experience.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2022
    Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

S RodríguezRadiation Oncology Department, Hospital Clínica Benidorm, Av. Alfonso Puchades 8, 30501, Benidorm, Alicante, Spain. atosrodriguez@gmail.com.ORCID http://orcid.org/0000-0002-4415-6563
M ArenasRadiation Oncology Department, Hospital Universitari Sant Joan de Reus, Tarragona, Spain.
C GutierrezRadiation Oncology Department, Institut Català d'Oncologia, Hospitalet de Llobregat, Catalonia, Spain.
J RichartRadiation Oncology Department, Hospital Clínica Benidorm, Av. Alfonso Puchades 8, 30501, Benidorm, Alicante, Spain.
J Perez-CalatayudRadiation Oncology Department, Hospital La Fe-IRIMED, Valencia, Spain.
F CeladaRadiation Oncology Department, Hospital La Fe-IRIMED, Valencia, Spain.
M SantosRadiation Oncology Department, Hospital Clínica Benidorm, Av. Alfonso Puchades 8, 30501, Benidorm, Alicante, Spain.
A RovirosaRadiation Oncology Department, ICMHO, Hospital Clínic I Universitari, Barcelona, Spain.
Hospital Clínica Benidorm · ESHospital Universitari de Vic · ESHospital Universitari Sant Joan de Reus · ESInstitut Català d'Oncologia · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Clinical indications of brachytherapy in non-melanoma skin cancers, description of applicators and dosimetry recommendations are described based on the literature review, clinical practice and experience of Spanish Group of Brachytherapy and Spanish Society of Medical Physics reported in the XIV Annual Consensus Meeting on Non Melanoma Skin Cancer Brachytherapy held in Benidorm, Alicante (Spain) on October 21st, 2016. All the recommendations for which consensus was achieved are highlighted in blue. Regular and small surfaces may be treated with Leipzig, Valencia, flap applicators or electronic brachytherapy (EBT). For irregular surfaces, customized molds or interstitial implants should be employed. The dose is prescribed at a maximum depth of 3-4 mm of the clinical target volume/planning target volume (CTV/PTV) in all cases except in flaps or molds in which 5 mm is appropriate. Interstitial brachytherapy should be used for CTV/PTV >5 mm. Different total doses and fraction sizes are used with very similar clinical and toxicity results. Hypofractionation is very useful twice or 3 times a week, being comfortable for patients and practical for Radiotherapy Departments. In interstitial brachytherapy 2 fractions twice a day are applied.

Indexed as

BrachytherapyHumansSkin NeoplasmsSpainConsensusDosimetric aspectsSkin brachytherapyTechnical

Identifiers

PMID28808925
OpenAlexW2750499055

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked