Evidence map›Paper›PMID 28808900›Full record

ArticleMedical & biological engineering & computing2018

Varying ultrasound power level to distinguish surgical instruments and tissue.

Hongliang Ren, Banani Anuraj, Pierre E Dupont

Open access · greenAbstract read
In one paragraph

Article in Medical & biological engineering & computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. High dynamic range ultrasound imaging.International journal of computer assisted radiology and surgery · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Hongliang RenDepartment of Biomedical Engineering, National University of Singapore, Singapore, Singapore. ren@nus.edu.sg.ORCID http://orcid.org/0000-0002-6488-1551
Banani AnurajDepartment of Biomedical Engineering, National University of Singapore, Singapore, Singapore.
Pierre E DupontDepartment of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, 300 Longwood Ave., Boston, MA, 02115, USA.
National University of Singapore · SGBoston Children's Hospital · US

Funding

Cardioscopically-guided Valve Repair in the Beating HeartR01HL124020 · NHLBI · BOSTON CHILDREN'S HOSPITAL · PI Pierre E Dupont · 2014 to 2026
$9.7M
Steerable MEMS Instruments for Precise Intracardiac SurgeryR01HL087797 · NHLBI · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI DUPONT, PIERRE E · 2007 to 2011
$5.1M
Ministry of Education - Singapore R-397-000-227-112National Institutes of Health R01HL087797National Institutes of Health R01HL124020National Medical Research Council (SG) R-397-000-245-511NHLBI NIH HHS R01 HL087797NHLBI NIH HHS R01 HL124020Singapore Millennium Foundation R-397-000-201-592
6 · The paper itself

Abstract

We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

Indexed as

Organ SpecificitySurgical InstrumentsUltrasonicsAnimalsHeartImaging, Three-DimensionalSus scrofaTransducersBeating-heart interventionsImage overlayMinimally invasive proceduresPower varyingSurgical roboticsUltrasound guidance

Identifiers

PMID28808900
PMCPMC6257990
OpenAlexW2748752050

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.