Evidence map›Paper›PMID 28800617›Full record

ArticlePloS one2017

Improved usability of a multi-infusion setup using a centralized control interface: A task-based usability test.

Frank Doesburg, Fokie Cnossen, Willem Dieperink, Wouter Bult, Anne Marie de Smet, Daan J Touw, Maarten W Nijsten

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 23 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Frank DoesburgUniversity of Groningen, University Medical Center Groningen, Department of Critical Care, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-9730-0792
Fokie CnossenUniversity of Groningen, Institute of Artificial Intelligence and Cognitive Engineering, Groningen, The Netherlands.
Willem DieperinkUniversity of Groningen, University Medical Center Groningen, Department of Critical Care, Groningen, The Netherlands.
Wouter BultUniversity of Groningen, University Medical Center Groningen, Department of Critical Care, Groningen, The Netherlands.
Anne Marie de SmetUniversity of Groningen, University Medical Center Groningen, Department of Critical Care, Groningen, The Netherlands.
Daan J TouwUniversity of Groningen, University Medical Center Groningen, Department of Clinical Pharmacy and Pharmacology, Groningen, The Netherlands.
Maarten W NijstenUniversity of Groningen, University Medical Center Groningen, Department of Critical Care, Groningen, The Netherlands.
University Medical Center Groningen · NLUniversity of Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40±3 vs. 73±20 clicks, p<0.001) and fewer user errors (1±1 vs. 3±2 errors, p<0.05), with no difference in task execution times (421±108 vs. 406±119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface.

Indexed as

Infusion PumpsUser-Computer InterfaceAdultCentralized Hospital ServicesHumansIntensive Care UnitsMiddle AgedMonitoring, PhysiologicNursing StationsSurveys and QuestionnairesTask Performance and Analysis

Identifiers

PMID28800617
PMCPMC5553772
OpenAlexW2742523565

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.