Comparison of stroke volume measurements during hemodialysis using bioimpedance cardiography and echocardiography.

Michael J Germain, Jyovani Joubert, Daniel O'Grady, Brian H Nathanson, Yossi Chait, Nathan W Levin

Abstract read
In one paragraph

Article in Hemodialysis international. International Symposium on Home Hemodialysis, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 23 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Observational
  9. Observational
  10. Observational
  11. Article
  12. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 6 institutions in 1 country.

Michael J GermainBaystate Medical Center, Springfield, Massachusetts and University of Massachusetts Medical School, Worcester, Massachusetts, USA.
Jyovani JoubertKidney Care and Transplant Associates of New England, Springfield, Massachusetts, USA.
Daniel O'GradyMercy Medical Center, Springfield, Massachusetts, USA.
Brian H NathansonOptiStatim, LLC, Longmeadow, Massachusetts, USA.
Yossi ChaitUniversity of Massachusetts, Amherst, Massachusetts, USA.
Nathan W LevinMt. Sinai Ichan School of Medicine, New York, USA.
Kidney Associates · USMercy Medical Center · USMount Sinai Hospital · USOptim Design (United States) · USUniversity of Massachusetts Amherst · USUniversity of Massachusetts Chan Medical School · US

Funding

The Engineering of Individualized Anemia Management ProtocolsK25DK096006 · NIDDK · UNIVERSITY OF MASSACHUSETTS AMHERST · PI CHAIT, YOSSI · 2013 to 2016
$670k
NIDDK NIH HHS K25 DK096006
6 · The paper itself

Abstract

backgroundFluid management remains a major challenge of hemodialysis (HD) care, with serious implications for morbidity and mortality. Intradialytic fluid management is typically guided by blood pressure, an indirect resultant of hemodynamics status. Direct measurements of hemodynamic parameters may improve cardiovascular outcomes by providing rational bases for intervention. We compare stroke volume (SV) measurements using a noninvasive, regional biompedance cardiography device (NiCaS) with Doppler echocardiography (Echo) in HD setting.

methodsStroke volumes were simultaneously measured using the devices in 17 patients receiving maintenance HD. Measurements were made during 2 weekly HD treatments, and twice within each HD treatment during the first and last hour of each treatment, for a total of 64 SV measurements. Agreement between devices was assessed using linear regression, a Pearson's correlation coefficient, and a Bland-Altman plot all adjusted for repeated measures within patients.

resultsEcho and NiCaS SV mean and 95% CIs were 58.0 (50.1, 65.8) and 56.7 (49.4, 64.0) mL, respectively. NiCaS SV correlated strongly with Echo SV during the first and last hours of treatments (r = 0.93, P < 0.001 and r = 0.92, P < 0.001, respectively). Linear regression of NiCaS on Echo showed a slope of 0.97, 95% CI (0.91, 1.02) which did not differ from 1, P = 0.20. A Bland-Altman plot and 4-Quadrant plot confirmed that the 2 methods produced comparable measurements.

conclusionNiCaS SV measurements are similar to and strongly correlated with Echo SV measurements. This suggests that noninvasive NiCaS technology may be a practical method for measuring SV during HD.

Indexed as

AgedCardiography, ImpedanceEchocardiography, DopplerFemaleHumansMaleMiddle AgedRenal DialysisStroke Volumebioimpedance cardiographyechocardiographyhemodialysisStroke volume

Identifiers

PMID28796425
PMCPMC5809229
OpenAlexW2744881149

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.