Evidence map›Paper›PMID 28795076›Full record

ArticleOrthopaedic journal of sports medicine2017

Intraoperative Radiation Exposure During Hip Arthroscopy.

John P Salvo, Jake Zarah, Zaira S Chaudhry, Kirsten L Poehling-Monaghan

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Is It Safe to Use a Lead Screen During Hip Arthroscopy?Arthroscopy, sports medicine, and rehabilitation · 2021
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

John P SalvoRothman Institute at Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
Jake ZarahRothman Institute at Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
Zaira S ChaudhryRothman Institute at Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
Kirsten L Poehling-MonaghanRothman Institute at Thomas Jefferson University, Philadelphia, Pennsylvania, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe frequency of hip arthroscopy for the treatment of acute and chronic chondrolabral pathology and femoroacetabular impingement (FAI) has increased exponentially over the past decade. While surgeon and patient radiation exposure has been well documented in other areas of the orthopaedic literature, little is known about the procedure-specific and cumulative doses affecting the hip arthroscopist. PURPOSE: To determine the mean annual radiation exposure to the hip arthroscopist and the mean surgeon exposure per case. STUDY

designCase series; Level of evidence, 4.

methodsA total of 210 consecutive hip arthroscopies performed in 209 patients by a single surgeon at a single ambulatory surgical center in a cohort consisting of approximately 50% bony (cam and pincer) pathology were prospectively reviewed, documenting the specific procedures performed in each case and the readings from a radiation dosimeter worn by the surgeon during positioning and while performing the procedures. Radiation readings for deep dose-equivalent (DDE), lens dose-equivalent (LDE), and shallow dose-equivalent (SDE) were measured. These readings were compared with the annual radiation dose limit recommendations established by the International Commission on Radiological Protection (ICRP).

resultsThe total radiation doses for the operative surgeon during all 210 cases were 183 mrem (1.83 mSv) DDE, 183 mrem (1.83 mSv) LDE, and 176 mrem (1.76 mSv) SDE. The mean exposure per case was 0.871 mrem (0.00871 mSv) DDE, 0.871 mrem (0.00871 mSv) LDE, and 0.838 mrem (0.00838 mSv) SDE. The operative surgeon's mean annual exposure, performing 70 hip arthroscopies per year with 55% involving bony work, was 61.0 mrem (0.610 mSv) DDE, 61.0 mrem (0.610 mSv) LDE, and 58.7 mrem (0.587 mSv) SDE. These results are well below the ICRP annual limits of 50,000 mrem (500 mSv) DDE, 2000 mrem (20 mSv) LDE, and 50,000 mrem (500 mSv) SDE.

conclusionFor an experienced hip arthroscopist utilizing fluoroscopy during setup and bony resection, the annual and per-patient exposure to radiation remains well below the recommended ICRP limits. CLINICAL RELEVANCE: Considering the increasing annual frequency of hip arthroscopies being performed, information regarding procedure-specific and cumulative doses of radiation exposure affecting the hip arthroscopist may provide valuable safety information for the orthopaedic community.

Indexed as

arthroscopyfluoroscopyhipradiation

Identifiers

PMID28795076
PMCPMC5524238

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.