ArticleOrthopaedic journal of sports medicine2017
Intraoperative Radiation Exposure During Hip Arthroscopy.
Article in Orthopaedic journal of sports medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Article
- Ultrasound Can Determine Joint Distraction During Hip Arthroscopy but Fluoroscopic-Guided Portal Placement Is Superior.Arthroscopy, sports medicine, and rehabilitation · 2022Article
- Is It Safe to Use a Lead Screen During Hip Arthroscopy?Arthroscopy, sports medicine, and rehabilitation · 2021Article
- Forget the Greater Trochanter! Hip Joint Access With the 12 O'clock Portal in Hip Arthroscopy.Arthroscopy techniques · 2019Article
- Retrospective Analysis of the Accuracy of Ultrasound-Guided Magnetic Resonance Arthrogram Injections of the Hip in the Office Setting.Orthopaedic journal of sports medicine · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe frequency of hip arthroscopy for the treatment of acute and chronic chondrolabral pathology and femoroacetabular impingement (FAI) has increased exponentially over the past decade. While surgeon and patient radiation exposure has been well documented in other areas of the orthopaedic literature, little is known about the procedure-specific and cumulative doses affecting the hip arthroscopist. PURPOSE: To determine the mean annual radiation exposure to the hip arthroscopist and the mean surgeon exposure per case. STUDY
designCase series; Level of evidence, 4.
methodsA total of 210 consecutive hip arthroscopies performed in 209 patients by a single surgeon at a single ambulatory surgical center in a cohort consisting of approximately 50% bony (cam and pincer) pathology were prospectively reviewed, documenting the specific procedures performed in each case and the readings from a radiation dosimeter worn by the surgeon during positioning and while performing the procedures. Radiation readings for deep dose-equivalent (DDE), lens dose-equivalent (LDE), and shallow dose-equivalent (SDE) were measured. These readings were compared with the annual radiation dose limit recommendations established by the International Commission on Radiological Protection (ICRP).
resultsThe total radiation doses for the operative surgeon during all 210 cases were 183 mrem (1.83 mSv) DDE, 183 mrem (1.83 mSv) LDE, and 176 mrem (1.76 mSv) SDE. The mean exposure per case was 0.871 mrem (0.00871 mSv) DDE, 0.871 mrem (0.00871 mSv) LDE, and 0.838 mrem (0.00838 mSv) SDE. The operative surgeon's mean annual exposure, performing 70 hip arthroscopies per year with 55% involving bony work, was 61.0 mrem (0.610 mSv) DDE, 61.0 mrem (0.610 mSv) LDE, and 58.7 mrem (0.587 mSv) SDE. These results are well below the ICRP annual limits of 50,000 mrem (500 mSv) DDE, 2000 mrem (20 mSv) LDE, and 50,000 mrem (500 mSv) SDE.
conclusionFor an experienced hip arthroscopist utilizing fluoroscopy during setup and bony resection, the annual and per-patient exposure to radiation remains well below the recommended ICRP limits. CLINICAL RELEVANCE: Considering the increasing annual frequency of hip arthroscopies being performed, information regarding procedure-specific and cumulative doses of radiation exposure affecting the hip arthroscopist may provide valuable safety information for the orthopaedic community.
Indexed as