Evidence map›Paper›PMID 28792891›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2017

Feasibility and Validation of 4-D Pulse Wave Imaging in Phantoms and In Vivo.

Iason-Zacharias Apostolakis, Pierre Nauleau, Clement Papadacci, Matthew D McGarry, Elisa E Konofagou

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.3field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. A New Plane Wave Compounding Scheme Using Phase Compensation for Motion Detection.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
  6. Article
  7. Article
  8. Pulse Wave Imaging Coupled With Vector Flow Mapping: A Phantom, Simulation, and In Vivo Study.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  9. Article
  10. 3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020
    Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Iason-Zacharias Apostolakis
Pierre Nauleau
Clement Papadacci
Matthew D McGarry
Elisa E Konofagou
Columbia University · USDartmouth College · US

Funding

Carotid plaque assessment using Pulse Wave ImagingR01HL135734 · NHLBI · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI KONOFAGOU, ELISA E. · 2017 to 2020
$2.5M
Noninvasive qualitative and quantitative assessment of vascular disease in vivoR01HL098830 · NHLBI · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI KONOFAGOU, ELISA E. · 2010 to 2013
$1.5M
NHLBI NIH HHS R01 HL098830NHLBI NIH HHS R01 HL135734
6 · The paper itself

Abstract

Pulse wave imaging (PWI) is a noninvasive technique for tracking the propagation of the pulse wave along the arterial wall. The 3-D ultrasound imaging would aid in objectively estimating the pulse wave velocity (PWV) vector. This paper aims to introduce a novel PWV estimation method along the propagation direction, validate it in phantoms, and test its feasibility in vivo. A silicone vessel phantom consisting of a stiff and a soft segment along the longitudinal axis and a silicone vessel with a plaque were constructed. A 2-D array with a center frequency of 2.5 MHz was used. Propagation was successfully visualized in 3-D in each phantom and in vivo in six healthy subjects. In three of the healthy subjects, results were compared against conventional PWI using a linear array. PWVs were estimated in the stiff (3.42 ± 0.23 m [Formula: see text]) and soft (2.41 ± 0.07 m [Formula: see text]) phantom segments. Good agreement was found with the corresponding static testing values (stiff: 3.41 m [Formula: see text] and soft: 2.48 m [Formula: see text]). PWI-derived vessel compliance values were validated with dynamic testing. Comprehensive views of pulse propagation in the plaque phantom were generated and compared against conventional PWI acquisitions. Good agreement was found in vivo between the results of 4-D PWI (4.80 ± 1.32 m [Formula: see text]) and conventional PWI (4.28±1.20 m [Formula: see text]) ( n=3 ). PWVs derived for all of the healthy subjects ( n = 6 ) were within the physiological range. Thus, the 4-D PWI was successfully validated in phantoms and used to image the pulse wave propagation in normal human subjects in vivo.

Indexed as

TransducersAdultCarotid Artery, CommonFeasibility StudiesHumansImaging, Three-DimensionalPhantoms, ImagingPulse Wave AnalysisYoung Adult

Identifiers

PMID28792891
PMCPMC5823504
OpenAlexW2745070086

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.