Evidence map›Paper›PMID 28782523›Full record

ArticleJournal of immunological methods2017

Monitoring native HLA-I trimer specific antibodies in Luminex multiplex single antigen bead assay: Evaluation of beadsets from different manufacturers.

Mepur H Ravindranath, Vadim Jucaud, Soldano Ferrone

Erratum issuedAbstract readComparative Study
In one paragraph

Article in Journal of immunological methods, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Mepur H RavindranathTerasaki Foundation Laboratory, Los Angeles, CA, United States. Electronic address: ravimh@terasakilab.org.
Vadim JucaudTerasaki Foundation Laboratory, Los Angeles, CA, United States.
Soldano FerroneDepartment of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States.

Funding

Antigen processing and HLA-peptide complexes in head and neck cancerR01CA110249 · NCI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI FERRONE, SOLDANO · 2006 to 2010
$1.5M
NCI NIH HHS R01 CA110249
6 · The paper itself

Abstract

Luminex single antigen bead (SAB) assay utilizes beadsets coated with a set of cloned and purified HLA molecules, for monitoring serum anti-HLA antibodies. Particularly, the level of serum IgG against native HLA-I trimers (heavy chain (HC) and β2-microglobulin (β2m) with a peptide), expressed in allograft tissues is correlated with graft failure. In addition to native trimeric HLAI, the beadsets may carry HC only or the dimeric variants, peptide-free HC with β2m and β2m-free HC with or without peptides. Currently, three different HLA-I coated beadsets have been produced commercially. The HLA antigen density on one beadset was reported to be approximately 50% of that present on another beadset as evidenced by the binding of an anti-HLA-I mAb W6/32. To date, no efforts have been made to compare the relative distribution of HLA-I variants in these three beadsets. In this study, using monoclonal antibodies (W6/32, HC-10 and TFL-006) that can distinguish the structural variants based on their epitope specificities, the nature of the variants in the three beadsets were comparatively evaluated. One beadset (Beadset A, see Materials and methods for Brand and Manufacturer's names) (W6/32+/HC-10+/TFL-006+) carried at least three variants, while beadset B (W6/32+/HC-10+/TFL-006-) carried two (peptide-associated and peptide-free β2m-HC) and the beadset C (W6/32+/HC-10-/TFL-006-) carried exclusively the HLA-I trimer suggesting its usefulness for specific monitoring native HLA-I trimer antibodies. Because of the salient differences in the variants coated on the different beadsets, it would be warranted to investigate, if these differences are clinically relevant for monitoring serum anti-HLA antibodies in sensitized patients waiting for donor organs and in allograft recipients (274).

Indexed as

Antibody SpecificityEpitopesHistocompatibilityAntibodies, MonoclonalHistocompatibility TestingHLA AntigensHumansImmunoassayImmunoglobulin GIsoantibodiesPredictive Value of TestsQuality ControlReproducibility of ResultsAntibodies, MonoclonalEpitopesHLA AntigensImmunoglobulin GIsoantibodies

Identifiers

PMID28782523
PMCPMC8715512

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.