ArticlePloS one2017
Optical sensing of anticoagulation status: Towards point-of-care coagulation testing.
Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 25 citations in OpenAlex.
- Assessing the micromechanical architecture of joint tissues with speckle rheological microscopy.Nature communications · 2026Article
- Speckle fluctuations reveal dynamics of microparticles in fibrin scaffolds in a model of bacterial infection.npj biological physics and mechanics · 2025Article
- Laser speckle rheological microscopy reveals wideband viscoelastic spectra of biological tissues.Science advances · 2024Article
- In-vivo mechanical characterization of coronary atherosclerotic plaques in living swine using intravascular laser speckle imaging.Biomedical optics express · 2021Article
- Comprehensive Blood Coagulation Profiling in Patients Using iCoagLab: Comparison Against Thromboelastography.Thrombosis and haemostasis · 2020Article
- Tutorial on laser speckle rheology: technology, applications, and opportunities.Journal of biomedical optics · 2020Review
- Laser speckle decorrelation time-based platelet function testing in microfluidic system.Scientific reports · 2019Article
- Hypothermia-induced activation of the splenic platelet pool as a risk factor for thrombotic disease in a mouse model.Journal of thrombosis and haemostasis : JTH · 2019Article
- Comprehensive Coagulation Profiling at the Point-of-Care Using a Novel Laser-Based Approach.Seminars in thrombosis and hemostasis · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
Anticoagulant overdose is associated with major bleeding complications. Rapid coagulation sensing may ensure safe and accurate anticoagulant dosing and reduce bleeding risk. Here, we report the novel use of Laser Speckle Rheology (LSR) for measuring anticoagulation and haemodilution status in whole blood. In the LSR approach, blood from 12 patients and 4 swine was placed in disposable cartridges and time-varying intensity fluctuations of laser speckle patterns were measured to quantify the viscoelastic modulus during clotting. Coagulation parameters, mainly clotting time, clot progression rate (α-angle) and maximum clot stiffness (MA) were derived from the clot viscoelasticity trace and compared with standard Thromboelastography (TEG). To demonstrate the capability for anticoagulation sensing in patients, blood samples from 12 patients treated with warfarin anticoagulant were analyzed. LSR clotting time correlated with prothrombin and activated partial thromboplastin time (r = 0.57-0.77, p<0.04) and all LSR parameters demonstrated good correlation with TEG (r = 0.61-0.87, p<0.04). To further evaluate the dose-dependent sensitivity of LSR parameters, swine blood was spiked with varying concentrations of heparin, argatroban and rivaroxaban or serially diluted with saline. We observed that anticoagulant treatments prolonged LSR clotting time in a dose-dependent manner that correlated closely with TEG (r = 0.99, p<0.01). LSR angle was unaltered by anticoagulation whereas TEG angle presented dose-dependent diminution likely linked to the mechanical manipulation of the clot. In both LSR and TEG, MA was largely unaffected by anticoagulation, and LSR presented a higher sensitivity to increased haemodilution in comparison to TEG (p<0.01). Our results establish that LSR rapidly and accurately measures the response of various anticoagulants, opening the opportunity for routine anticoagulation monitoring at the point-of-care or for patient self-testing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials