Evidence map›Paper›PMID 28770993›Full record

ArticleACS applied materials & interfaces2017

Real-Time Monitoring of Insulin Using a Graphene Field-Effect Transistor Aptameric Nanosensor.

Zhuang Hao, Yibo Zhu, Xuejun Wang, Pavana G Rotti, Christopher DiMarco, Scott R Tyler, Xuezeng Zhao, John F Engelhardt, James Hone, Qiao Lin

Open access · greenAbstract read
In one paragraph

Article in ACS applied materials & interfaces, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers.

0numbers the graph read from it
0cells of the map it votes in
38citing papers in PubMed
5.3field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

38 citing papers in PubMed, 137 citations in OpenAlex.

  1. Review
  2. Review
  3. Recent Advances in Xenes Based FET for Biosensing Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  4. Review
  5. Article
  6. Article
  7. Modular Fabrication of Microfluidic Graphene FET for Nucleic Acids Biosensing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  8. 2D Materials in Advanced Electronic Biosensors for Point-of-Care Devices.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Review
  9. Aptameric Metal-Organic Framework Nanobiosensor.ACS applied nano materials · 2024
    Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Review
  15. Clinical Evaluation of a Novel Insulin Immunosensor.Journal of diabetes science and technology · 2023
    Article
  16. Review
  17. Article
  18. Review
  19. Chemical Sensor Nanotechnology in Pharmaceutical Drug Research.Nanomaterials (Basel, Switzerland) · 2022
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Zhuang HaoDepartment of Mechanical Engineering, Columbia University , New York, New York 10027, United States.ORCID http://orcid.org/0000-0003-4776-6022
Yibo ZhuDepartment of Mechanical Engineering, Columbia University , New York, New York 10027, United States.
Xuejun WangDepartment of Mechanical Engineering, Columbia University , New York, New York 10027, United States.
Pavana G Rotti
Christopher DiMarcoDepartment of Mechanical Engineering, Columbia University , New York, New York 10027, United States.
Scott R Tyler
Xuezeng ZhaoDepartment of Mechanical Engineering, Harbin Institute of Technology , Harbin, Heilongjiang 150001, China.
John F Engelhardt
James HoneDepartment of Mechanical Engineering, Columbia University , New York, New York 10027, United States.
Qiao LinDepartment of Mechanical Engineering, Columbia University , New York, New York 10027, United States.
Columbia University · USHarbin Institute of Technology · CN

Funding

Pulmonary Toxicology Facility CoreP30ES005605 · NIEHS · UNIVERSITY OF IOWA · PI Brandi Janssen · 1990 to 2026
$40.5M
Validating Rapid Microfluidic Isolation of Personalized Aptamers for Monitoring Minimal Residual Disease in Multiple MyelomaR33CA196470 · NCI · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI LIN, QIAO · 2016 to 2018
$1.2M
A Differential Dielectric Affinity Microsensor for Stable and Accurate Glucose MoDP3DK101085 · NIDDK · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI LIN, QIAO · 2013 to 2013
$1.1M
NCI NIH HHS R33 CA196470NIDDK NIH HHS DP3 DK101085
6 · The paper itself

Abstract

This paper presents an approach to the real-time, label-free, specific, and sensitive monitoring of insulin using a graphene aptameric nanosensor. The nanosensor is configured as a field-effect transistor, whose graphene-based conducting channel is functionalized with a guanine-rich IGA3 aptamer. The negatively charged aptamer folds into a compact and stable antiparallel or parallel G-quadruplex conformation upon binding with insulin, resulting in a change in the carrier density, and hence the electrical conductance, of the graphene. The change in the electrical conductance is then measured to enable the real-time monitoring of insulin levels. Testing has shown that the nanosensor offers an estimated limit of detection down to 35 pM and is functional in Krebs-Ringer bicarbonate buffer, a standard pancreatic islet perfusion medium. These results demonstrate the potential utility of this approach in label-free monitoring of insulin and in timely prediction of accurate insulin dosage in clinical diagnostics.

Indexed as

Biosensing TechniquesG-QuadruplexesGraphiteInsulinIslets of LangerhansGraphiteInsulinaffinity sensingaptamerG-quadruplexgraphene field-effect transistor (GFET)insulin

Identifiers

PMID28770993
PMCPMC7875320
OpenAlexW2743494022

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.