Broadband Prosthetic Interfaces: Combining Nerve Transfers and Implantable Multichannel EMG Technology to Decode Spinal Motor Neuron Activity.
Article in Frontiers in neuroscience, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Experimental Testing of Bionic Peripheral Nerve and Muscle Interfaces: Animal Model Considerations.Frontiers in neuroscience · 2019Pooled it
- Implanted microelectrode arrays in reinnervated muscles allow separation of neural drives from transferred polyfunctional nerves.Nature biomedical engineering · 2026Article
- Reinnervation of Muscle Targets Enhances the Separability of Motor Unit Signals Following Peripheral Nerve Transfers.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- The Future of Biohybrid Regenerative Bioelectronics.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- Creation of a biological sensorimotor interface for bionic reconstruction.Nature communications · 2024Article
- New insights into muscle activity associated with phantom hand movements in transhumeral amputees.Frontiers in human neuroscience · 2024Article
- Toward higher-performance bionic limbs for wider clinical use.Nature biomedical engineering · 2023Review
- An Algorithm for Elective Amputation Combined with Targeted Muscle Reinnervation in Complex Regional Pain Syndrome-A Perspective.Journal of personalized medicine · 2022Article
- Wearable super-resolution muscle-machine interfacing.Frontiers in neuroscience · 2022Review
- Article
- Avian extremity reconstruction via osseointegrated leg-prosthesis for intuitive embodiment.Scientific reports · 2021Article
- Prosthesis and the engineered imagination: reading augmentation and disability across cultural theory, representation and product design.Medical humanities · 2020Article
- Bionic Upper Limb Reconstruction: A Valuable Alternative in Global Brachial Plexus Avulsion Injuries-A Case Series.Journal of clinical medicine · 2019Article
- Bionic reconstruction : Restoration of extremity function with osseointegrated and mind-controlled prostheses.Wiener klinische Wochenschrift · 2019Article
- Hard-wired Epimysial Recordings from Normal and Reinnervated Muscle Using a Bone-anchored Device.Plastic and reconstructive surgery. Global open · 2019Article
- Rehabilitation of Upper Extremity Nerve Injuries Using Surface EMG Biofeedback: Protocols for Clinical Application.Frontiers in neuroscience · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Modern robotic hands/upper limbs may replace multiple degrees of freedom of extremity function. However, their intuitive use requires a high number of control signals, which current man-machine interfaces do not provide. Here, we discuss a broadband control interface that combines targeted muscle reinnervation, implantable multichannel electromyographic sensors, and advanced decoding to address the increasing capabilities of modern robotic limbs. With targeted muscle reinnervation, nerves that have lost their targets due to an amputation are surgically transferred to residual stump muscles to increase the number of intuitive prosthetic control signals. This surgery re-establishes a nerve-muscle connection that is used for sensing nerve activity with myoelectric interfaces. Moreover, the nerve transfer determines neurophysiological effects, such as muscular hyper-reinnervation and cortical reafferentation that can be exploited by the myoelectric interface. Modern implantable multichannel EMG sensors provide signals from which it is possible to disentangle the behavior of single motor neurons. Recent studies have shown that the neural drive to muscles can be decoded from these signals and thereby the user's intention can be reliably estimated. By combining these concepts in chronic implants and embedded electronics, we believe that it is in principle possible to establish a broadband man-machine interface, with specific applications in prosthesis control. This perspective illustrates this concept, based on combining advanced surgical techniques with recording hardware and processing algorithms. Here we describe the scientific evidence for this concept, current state of investigations, challenges, and alternative approaches to improve current prosthetic interfaces.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.