ArticleBMC medical imaging2017
Detection of articular perforations of the proximal humerus fracture using a mobile 3D image intensifier - a cadaver study.
Article in BMC medical imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 7 citations in OpenAlex.
- 3D C-arm navigated suture button implantation for AC joint dislocations - the pilot study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024Article
- Intraoperative 3D imaging in plate osteosynthesis of proximal humerus fractures.Archives of orthopaedic and trauma surgery · 2023Article
- Optimal viewing angles of intraoperative fluoroscopy for detecting screw penetration in proximal humeral fractures: a cadaveric study.BMC musculoskeletal disorders · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe purpose of this study was to investigate the accuracy of perforation detection with multiplanar reconstructions using a mobile 3D image intensifier.
methodsIn 12 paired human humeri, K-wires perforating the subchondral bone and placed just below the cartilage level were directed toward five specific regions in the humeral head. Image acquisition was initiated by a fluoroscopy scan. Within a range of 90°, 45° external rotation (ER) and 45° internal rotation (IR). The number and percentage of detected perforating screws were grouped and analyzed. Furthermore, the fluoroscopic images were converted into multiplanar CT-like reconstructions. Each K-wire perforation was characterized as "detected" or "not detected".
resultsIn the series of fluoroscopy images in the standard neutral position at 30° internal rotation, and 30° external rotation, the perforations of all K-wires (n = 56) were detected. Twenty-nine (51.8%) of them were detected in one AP view, 22 (39.3%) in two AP views, and five (8.9%) in three AP views. All K-wire perforations (100%, n = 56) were detected in multiplanar reconstructions.
conclusionIn order to reveal all of the intraoperative and postoperative screw perforations in a "five screw configuration", conventional AP images should be established in both the neutral positions (0°), at 30° internal rotation and 30° external rotation. Alternatively, the intraoperative 3D scan with multiplanar reconstructions enables a 100% rate of detection of the screw perforations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials