Evidence map›Paper›PMID 28759840›Full record

ArticleJournal of the mechanical behavior of biomedical materials2017

An experimental canine patent ductus arteriosus occlusion device based on shape memory polymer foam in a nitinol cage.

Mark A Wierzbicki, Sarah B Raines, Sonya G Gordon, John C Criscione, Ashley B Saunders, Scott Birch, Bradley Due, Brandis Keller, Landon D Nash, Matthew W Miller and 1 more

Open access · greenAbstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 17 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Mark A WierzbickiDepartment of Biomedical Engineering, Texas A&M University, MS 3120, 5045 Emerging Technologies Building, College Station, TX 77843, USA.
Sarah B RainesDepartment of Electrical Engineering, Texas A&M University, USA.
Sonya G GordonDepartment of Small Animal Clinical Sciences of Veterinary Medicine and Biomedical Sciences, Texas A&M University, USA.
John C CriscioneDepartment of Biomedical Engineering, Texas A&M University, MS 3120, 5045 Emerging Technologies Building, College Station, TX 77843, USA.
Ashley B SaundersDepartment of Small Animal Clinical Sciences of Veterinary Medicine and Biomedical Sciences, Texas A&M University, USA.
Scott BirchThe Center for Educational Technologies, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, USA.
Bradley DueDepartment of Biomedical Engineering, Texas A&M University, MS 3120, 5045 Emerging Technologies Building, College Station, TX 77843, USA.
Brandis KellerDepartment of Biomedical Engineering, Texas A&M University, MS 3120, 5045 Emerging Technologies Building, College Station, TX 77843, USA.
Landon D NashDepartment of Biomedical Engineering, Texas A&M University, MS 3120, 5045 Emerging Technologies Building, College Station, TX 77843, USA.
Matthew W MillerTexas Institute for Preclinical Studies, Texas A&M University, MS 4478, College Station, TX 77845, USA.
Duncan J MaitlandDepartment of Biomedical Engineering, Texas A&M University, MS 3120, 5045 Emerging Technologies Building, College Station, TX 77843, USA. Electronic address: djmaitland@tamu.edu.
Texas A&M University · US

Funding

Shape Memory Polymer Embolic Foams for Treating Cerebrovascular AneurysmsU01NS089692 · NINDS · TEXAS ENGINEERING EXPERIMENT STATION · PI MAITLAND, DUNCAN J · 2015 to 2018
$2.5M
NINDS NIH HHS U01 NS089692
6 · The paper itself

Abstract

Patent ductus arteriosus (PDA) is a congenital cardiovascular defect in which a fetal connection between the aorta and pulmonary artery does not spontaneously close shortly after birth. If left uncorrected serious complications and even death can occur. Surgical ligation is the traditional treatment method; however, it is an invasive procedure, that motivates development of a minimally invasive option. Shape memory polymer (SMP) foams are unique materials that hold promise in the field of minimally invasive occlusion devices. In this work, a prototype nitinol foam cage (NFC) incorporating SMP foams has been designed and evaluated in multiple mechanical and in vitro verification tests. The NFC demonstrated acceptable fatigue resistance in a preliminary strut integrity test, withstanding one million cycles without complete strut fracture. Radial force analysis of both thick- and thin-walled prototype variations generated less vessel distension and wall tension in a vessel mimic compared to a commercial device. The NFCs exhibited negligible in vitro migration, comparable to that of a commercial device, using simplified, ideal models of PDA. Deployment characteristics of the prototypes were evaluated and compared to that of a commercial device when delivered into physiological models of PDA. During mock deployments, a veterinary cardiologist noted that, while deliverable, the thin-walled NFC prototype exhibited poor deployment characteristics, however the thick-walled NFC had deployment characteristics comparable to that of a commercial device. The promising results of this study warrant further investigation of the NFC device for canine PDA closure.

Indexed as

AlloysStentsAnimalsDogsDuctus Arteriosus, PatentPolymersPulmonary ArteryTherapeutic OcclusionAlloysnitinolPolymersACDOPatent ductus arteriosusShape memory polymer

Identifiers

PMID28759840
PMCPMC5823275
OpenAlexW2739468623

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.