Evidence map›Paper›PMID 28757564›Full record

ReviewSensors (Basel, Switzerland)2017

A Brief Review of OPT101 Sensor Application in Near-Infrared Spectroscopy Instrumentation for Intensive Care Unit Clinics.

Ting Li, Fulin Zhong, Boan Pan, Zebin Li, Chong Huang, Zishan Deng

Open access · goldAbstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.0field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 29 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Ting LiSchool of Microelectronics and Solid-state electronics, University of Electronic Science & Technology of China, Chengdu 610054, China. liting@uestc.edu.cn.
Fulin ZhongSchool of Microelectronics and Solid-state electronics, University of Electronic Science & Technology of China, Chengdu 610054, China. 201521031005@std.uestc.edu.cn.
Boan PanSchool of Microelectronics and Solid-state electronics, University of Electronic Science & Technology of China, Chengdu 610054, China. 201621030444@std.uestc.edu.cn.
Zebin LiSchool of Microelectronics and Solid-state electronics, University of Electronic Science & Technology of China, Chengdu 610054, China. 201521031032@std.uestc.edu.cn.
Chong HuangDepartment of Biomedical Engineering, University of Kentucky, Lexington, Kentucky, KY 40506, USA. chong.huang@uky.edu.
Zishan DengSchool of Microelectronics and Solid-state electronics, University of Electronic Science & Technology of China, Chengdu 610054, China. 2013030102028@std.uestc.edu.cn.
University of Electronic Science and Technology of China · CNChinese Academy of Medical Sciences & Peking Union Medical College · CNUniversity of Kentucky · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The optoelectronic sensor OPT101 have merits in advanced optoelectronic response characteristics at wavelength range for medical near-infrared spectroscopy and small-size chip design with build-in trans-impedance amplifier. Our lab is devoted to developing a series of portable near-infrared spectroscopy (NIRS) devices embedded with OPT101 for applications in intensive care unit clinics, based on NIRS principle. Here we review the characteristics and advantages of OPT101 relative to clinical NIRS instrumentation, and the most recent achievements, including early-diagnosis and therapeutic effect evaluation of thrombus, noninvasive monitoring of patients' shock severity, and fatigue evaluation. The future prospect on OPT101 improvements in noninvasive clinical applications is also discussed.

Indexed as

Spectroscopy, Near-InfraredHumansIntensive Care Unitsfatigue evaluationnear-infrared spectroscopyoptoelectronic sensorshock monitoringthrombus diagnosis

Identifiers

PMID28757564
PMCPMC5580117
OpenAlexW2738587610

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.