ArticleRadiology2017
Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans.
Article in Radiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03878134 (Translational Development of Photon-Counting CT Imaging), which is not on this map. Cited by 90 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Translational Development of Photon-Counting CT Imaging
Who cites it
90 citing papers in PubMed, 184 citations in OpenAlex.
- Quantitative and qualitative lung parameters in photon-counting CT: comparison of ultra-low-dose with standard low-dose protocols.European radiology · 2026Article
- Photon-counting CT for hepato-bilio-pancreatic imaging: a qualitative head-to-head comparison with third-generation dual-source CT: preliminary results.La Radiologia medica · 2026Article
- Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT-Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions.European radiology · 2026Article
- Overview of dose optimization methods for patient safety in current CT technologies.Physical and engineering sciences in medicine · 2026Article
- Multispectral PCCT and CBCT imaging for high precision radiotherapy through translation of imaging parameters with machine learning validation.Scientific reports · 2026Article
- Reduction of radiation exposure and preserved image quality using photon-counting detector cardiac computed tomography without electrocardiographic gating in children with congenital heart disease.European radiology · 2026Article
- Photon-Counting Chest CT at Radiography-Comparable Dose Levels: Impact on Opportunistic Visual and Semiautomated Coronary Calcium Quantification.Investigative radiology · 2026Article
- Photon-counting CT angiography in a multi-trauma patient with bilateral pulmonary embolism: combined vascular mapping and quantitative iodine-density assessment prior to scalp reconstruction: case report.Frontiers in medicine · 2026Article
- Development of a LASSO dynamic prediction system for interbody cage subsidence following OLIF surgery.NPJ digital medicine · 2025Article
- Comparison of quantitative lung measures in low dose energy-integrating detector and photon-counting detector chest CT with an anthropomorphic phantom.Biomedical physics & engineering express · 2025Article
- Applicability of Effective Atomic Number (Zeff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography.Investigative radiology · 2025Article
- Advances in radiation protection related to pediatric chest computed tomography examinations.World journal of radiology · 2025Review
- Influence of phantom design on evaluation metrics in photon counting spectral head CT: a simulation study.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Optimizing Imaging Parameters for Assessment of Hepatocellular Carcinoma Using Photon-Counting Detector Computed Tomography-Impact of Reconstruction Kernel and Slice Thickness.Tomography (Ann Arbor, Mich.) · 2025Article
- Photon-counting CT in cancer radiotherapy: technological advances and clinical benefits.Physics in medicine and biology · 2025Review
- Review
- Cranial and spinal computed tomography (CT) angiography with photon-counting detector CT: comparison with angiographic and operative findings.Japanese journal of radiology · 2025Review
- Value of Ultrahigh-Resolution Photon-Counting Detector Computed Tomography in Cardiac Imaging.Echocardiography (Mount Kisco, N.Y.) · 2025Review
- Coronary CT Angiography in the Emergency Department: State of the Art and Future Perspectives.Journal of cardiovascular development and disease · 2025Review
- The United States Department of Energy and National Institutes of Health Collaboration: Medical Care Advances by Discovery in Radiation Detection.Medical physics · 2024Article
30 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 1 institution in 1 country.
Funding
Abstract
Purpose To investigate whether photon-counting detector (PCD) technology can improve dose-reduced chest computed tomography (CT) image quality compared with that attained with conventional energy-integrating detector (EID) technology in vivo. Materials and Methods This was a HIPAA-compliant institutional review board-approved study, with informed consent from patients. Dose-reduced spiral unenhanced lung EID and PCD CT examinations were performed in 30 asymptomatic volunteers in accordance with manufacturer-recommended guidelines for CT lung cancer screening (120-kVp tube voltage, 20-mAs reference tube current-time product for both detectors). Quantitative analysis of images included measurement of mean attenuation, noise power spectrum (NPS), and lung nodule contrast-to-noise ratio (CNR). Images were qualitatively analyzed by three radiologists blinded to detector type. Reproducibility was assessed with the intraclass correlation coefficient (ICC). McNemar, paired t, and Wilcoxon signed-rank tests were used to compare image quality. Results Thirty study subjects were evaluated (mean age, 55.0 years ± 8.7 [standard deviation]; 14 men). Of these patients, 10 had a normal body mass index (BMI) (BMI range, 18.5-24.9 kg/m
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.