ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2017
Accuracy of 3D fluoro-navigated anterior transpedicular screws in the subaxial cervical spine: an experimental study on human specimens.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Accuracy of robot-assisted anterior transpedicular screws in the subaxial cervical spine: an experimental study on human specimens.Frontiers in robotics and AI · 2025Article
- Measurement of anatomical parameters of anterior transpedicular root screw intervertebral fusion system of cervical spine.BMC musculoskeletal disorders · 2023Article
- Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation-A Retrospective Comparison with Conventional Pedicle Screw Implantation.Global spine journal · 2023Article
- Individualized 3D printed navigation template-assisted atlantoaxial pedicle screws vs. free-hand screws for the treatment of upper cervical fractures.Frontiers in surgery · 2022Article
- Intraoperative image guidance for cervical spine surgery.Annals of translational medicine · 2021Review
- Progress of the Anterior Transpedicular Screw in Lower Cervical Spine: A Review.Medical science monitor : international medical journal of experimental and clinical research · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionPedicle screw stabilization, the standard technique in the thoracic and lumbar spine, is increasingly used in the cervical spine. Initial studies on the use of anterior pedicle screws (ATPS) in the cervical spine have been recently published. ATPS use has theoretical advantages over posterior stabilization. We have already established a 3D-fluoroscopy navigation setup in a study of artificial bones. The aim of the current study was to evaluate the positioning quality/accuracy of ATPS introduced to human specimens.
methods36 cannulated screws (3.5 mm) were implanted anteriorly into the C3-C7 segments of four spines (unfixed, frozen, cadaveric specimens) using a 3D-fluoroscopy navigation system. Placement accuracy was evaluated using a recently published classification on postoperative CT scans. Grade 1 is perfect position with pedicle wall perforation <1 mm, grade 2 is perforation <2 mm, etc., and finally grade 5 is cortical perforation of >4 mm and/or transverse foramen entry.
results36 anterior pedicle screws were inserted into four human cervical spine specimens. Of these, seven screws were introduced to C3, five to C4 and eight each to C5, C6, and C7. Classified with the modified G&R, 21 of 36 (58.3%) were grade 1. Ten screws (27.8%) were grade 2. Grade 4 was assessed for two screws and grade 5 for three. Customary "good" positioning, combining grades 1 and 2, was thus found in 86.1%. Five screws (13.9%) did not meet this criterion (grade ≥3).
conclusionsWith 86.1% of good positioning (grade 2 or better), a 3D-fluoroscopy navigation of ATPS screws into human c-spine specimens achieved a satisfying results. These are at least comparable to results presented in the literature for posteriorly introduced subaxial pedicle screws.
Indexed as
Identifiers
28752244What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.