Evidence map›Paper›PMID 28748292›Full record

ArticleArchives of orthopaedic and trauma surgery2017

Systematic CT evaluation of reduction and hardware positioning of surgically treated calcaneal fractures: a reliability analysis.

R J O de Muinck Keizer, M S H Beerekamp, D T Ubbink, L F M Beenen, T Schepers, J C Goslings

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

R J O de Muinck KeizerTrauma Unit, G4-137, Department of Surgery, Academic Medical Center, PO-box 22660, 1100 DD, Amsterdam, The Netherlands. rjodemuinckkeizer@amc.nl.ORCID http://orcid.org/0000-0001-7370-7785
M S H BeerekampTrauma Unit, G4-137, Department of Surgery, Academic Medical Center, PO-box 22660, 1100 DD, Amsterdam, The Netherlands.
D T UbbinkDepartment of Surgery, Academic Medical Center, Amsterdam, The Netherlands.
L F M BeenenDepartment of Radiology, Academic Medical Center, Amsterdam, The Netherlands.
T SchepersTrauma Unit, G4-137, Department of Surgery, Academic Medical Center, PO-box 22660, 1100 DD, Amsterdam, The Netherlands.
J C GoslingsTrauma Unit, G4-137, Department of Surgery, Academic Medical Center, PO-box 22660, 1100 DD, Amsterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionUp to date, there is a lack of reliable protocols that systematically evaluate the quality of reduction and hardware positioning of surgically treated calcaneal fractures. Based on international consensus, we previously introduced a 23-item scoring protocol evaluating the reduction and hardware positioning in these fractures based on postoperative computed tomography. The current study is a reliability analysis of the described scoring protocol.

methodsThree raters independently and systematically evaluated anonymized postoperative CT scans of 102 surgically treated calcaneal fractures. A selection of 25 patients was scored twice by all individual raters to calculate intra-rater reliability. The scoring protocol consisted of 23 items addressing quality of reduction and hardware positioning. Each of these four-option questions was answered as: 'optimal', 'suboptimal (but not needing revision)', 'not acceptable (needing revision)' or 'not judgeable'. We used intraclass correlation coefficients (ICC's) to calculate inter- and intra-rater reliability.

resultsInter-rater reliability of the overall 23-item protocol was good (ICC 0.66, 95% CI 0.64-0.69). Individual items that scored an inter-rater ICC ≥0.60 included evaluation of the calcaneocuboid joint, the posterior talocalcaneal joint, the anterior talocalcaneal joint, the position of the plate and sustentaculum screws and screws protruding the tuber and medial wall. The intra-rater reliability for the overall protocol was good for all three individual raters with ICC's between 0.60 and 0.70.

conclusionOur scoring protocol for the radiological evaluation of operatively treated calcaneal fractures is reliable in terms of inter- and intra-rater reliability.

Indexed as

Ankle InjuriesCalcaneusInternal FixatorsCohort StudiesFracture Fixation, InternalHumansReproducibility of ResultsTomography, X-Ray ComputedTreatment OutcomeCalcaneusComputed tomographyEvaluationFractureSurgical treatment

Identifiers

PMID28748292
PMCPMC5565655

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.