Observational studyClinical neuroradiology2017
Brain relaxometry after macrocyclic Gd-based contrast agent.
Observational study in Clinical neuroradiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 12 citations in OpenAlex.
- Absence of T1 Hyperintensity in the Brain of High-risk Patients After Multiple Administrations of High-dose Gadobutrol for Cardiac Magnetic Resonance.Clinical neuroradiology · 2021Article
- Standardized assessment of the signal intensity increase on unenhanced T1-weighted images in the brain: the European Gadolinium Retention Evaluation Consortium (GREC) Task Force position statement.European radiology · 2019Review
- Gadolinium Retention in the Brain: An MRI Relaxometry Study of Linear and Macrocyclic Gadolinium-Based Contrast Agents in Multiple Sclerosis.AJNR. American journal of neuroradiology · 2019Article
- T1-weighted Grey Matter Signal Intensity Alterations After Multiple Administrations of Gadobutrol in Patients with Multiple Sclerosis, Referenced to White Matter.Scientific reports · 2018Article
- Prof. Dr. F. E. Zanella-A Training and Development Mentor in Neuroradiology.Clinical neuroradiology · 2017Article
- Gadobutrol in India-A Comprehensive Review of Safety and Efficacy.Magnetic resonance insights · 2017Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo assess if ratios of T1-weighted (T1w) signal intensity (SI) and quantitative T1 relaxometry (qT1) change on serial administration of macrocyclic gadobutrol.
methodsA total of 17 glioblastoma patients were scanned at 3.0 T magnetic resonance imaging (MRI) every 6 weeks after tumor resection with standard MRI and T1 and T2 relaxometry before and after gadobutrol administration. On co-registered images T1w SI was measured and relaxation times T1 (qT1) and quantitative T2 (qT2) were quantified in several deep grey matter nuclei as ratios relative to frontal white matter and to the pons. Ratio changes were evaluated over time with a paired t‑test and multiple regression.
resultsAn average of 8 (range 5-14) scans per patient were completed. Ratios of T1w SI, qT1 and qT2 remained unchanged for all target regions from the first to the last time point (p > 0.05) and did not correlate with the number of gadobutrol administrations. Multivariate regression showed no significant impact of gadobutrol on qT1 or qT2 ratios, but a significant negative effect on T1w SI ratios. Gender also had no impact on the ratios but age had a significant negative influence on the qT1 ratio.
conclusionMultiple administrations of a macrocyclic contrast agent did not change relaxation time T1 ratios in any deep grey matter structure.