ArticleBiosensors & bioelectronics2018
Sliding-strip microfluidic device enables ELISA on paper.
Article in Biosensors & bioelectronics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed, 144 citations in OpenAlex.
- Recent advances in the biosensing platforms for sepsis diagnosis.RSC advances · 2026Review
- Point of care sepsis diagnosis: Exploring microfluidic techniques for sample preparation, biomarker isolation, and detection.Biomicrofluidics · 2025Review
- Paper-Based Vertical Flow Assays for in Vitro Diagnostics and Environmental Monitoring.ACS sensors · 2025Review
- Enhanced Sensitivity Mach-Zehnder Interferometer-Based Tapered-in-Tapered Fiber-Optic Biosensor for the Immunoassay of C-Reactive Protein.Biosensors · 2025Article
- Comparison of protein immobilization methods with covalent bonding on paper for paper-based enzyme-linked immunosorbent assay.Analytical and bioanalytical chemistry · 2024Article
- Capillary flow-driven immunoassay platform for COVID-19 antigen diagnostics.Analytica chimica acta · 2023Article
- Battery-free and AI-enabled multiplexed sensor patches for wound monitoring.Science advances · 2023Article
- Capillary driven microfluidic sequential flow device for point-of-need ELISA: COVID-19 serology testing.Analytical methods : advancing methods and applications · 2023Article
- Engineering Innovative Interfaces for Point-of-Care Diagnostics.Current opinion in colloid & interface science · 2023Review
- Biophysical and biochemical insights in the design of immunoassays.Biochimica et biophysica acta. General subjects · 2023Review
- Current Advancements and Future Road Map to Develop ASSURED Microfluidic Biosensors for Infectious and Non-Infectious Diseases.Biosensors · 2022Review
- Development and Evaluation of a Paper-Based Microfluidic Device for Detection ofFoods (Basel, Switzerland) · 2022Article
- A paper-based colorimetric molecular test for SARS-CoV-2 in saliva.Biosensors & bioelectronics: X · 2021Article
- Capillary flow control in lateral flow assays via delaminating timers.Science advances · 2021Article
- Review
- Paper-Based Screen-Printed Electrodes: A New Generation of Low-Cost Electroanalytical Platforms.Biosensors · 2021Review
- Recent Advances of Hepatitis B Detection towards Paper-Based Analytical Devices.TheScientificWorldJournal · 2021Review
- Recent Advances of Fluid Manipulation Technologies in Microfluidic Paper-Based Analytical Devices (μPADs) toward Multi-Step Assays.Micromachines · 2020Review
- Atom transfer radical polymer-modified paper for improvement in protein fixation in paper-based ELISA.BMC chemistry · 2019Article
- Two Potential Clinical Applications of Origami-Based Paper Devices.Diagnostics (Basel, Switzerland) · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This article describes a 3D microfluidic paper-based analytical device that can be used to conduct an enzyme-linked immunosorbent assay (ELISA). The device comprises two parts: a sliding strip (which contains the active sensing area) and a structure surrounding the sliding strip (which holds stored reagents-buffers, antibodies, and enzymatic substrate-and distributes fluid). Running an ELISA involves adding sample (e.g. blood) and water, moving the sliding strip at scheduled times, and analyzing the resulting color in the sensing area visually or using a flatbed scanner. We demonstrate that this device can be used to detect C-reactive protein (CRP)-a biomarker for neonatal sepsis, pelvic inflammatory disease, and inflammatory bowel diseases-at a concentration range of 1-100ng/mL in 1000-fold diluted blood (1-100µg/mL in undiluted blood). The accuracy of the device (as characterized by the area under the receiver operator characteristics curve) is 89% and 83% for cut-offs of 10ng/mL (for neonatal sepsis and pelvic inflammatory disease) and 30ng/mL (for inflammatory bowel diseases) CRP in 1000-fold diluted blood respectively. In resource-limited settings, the device can be used as a part of a kit (containing the device, a fixed-volume capillary, a pre-filled tube, a syringe, and a dropper); this kit would cost ~ $0.50 when produced in large scale (>100,000 devices/week). This kit has the technical characteristics to be employed as a pre-screening tool, when combined with other data such as patient history and clinical signs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.