Evidence map›Paper›PMID 28736469›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2017

Improved Automatic Optic Nerve Radius Estimation from High Resolution MRI.

Robert L Harrigan, Alex K Smith, Louise A Mawn, Seth A Smith, Bennett A Landman

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Quantitative characterization of optic nerve atrophy in patients with multiple sclerosis.Multiple sclerosis journal - experimental, translational and clinical
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Robert L HarriganElectrical Engineering, Vanderbilt University, Nashville, TN, USA 37235.
Alex K SmithBiomedical Engineering, Vanderbilt University, Nashville, TN, USA 37235.
Louise A MawnOphthalmology and Neurological Surgery, Vanderbilt University, Nashville, TN, USA 37232.
Seth A SmithInstitute for Imaging Science, Vanderbilt University, Nashville, TN, USA 37235.
Bennett A LandmanElectrical Engineering, Vanderbilt University, Nashville, TN, USA 37235.
Vanderbilt University · US

Funding

VANDERBILT UNIVERSITY CTSA FOR PEDIATRIC RESEARCHUL1RR024975 · NCRR · VANDERBILT UNIVERSITY · PI BERNARD, GORDON RAPHAEL · 2007 to 2011
$45.7M
The Vanderbilt Institute for Clinical and Translational Research (VICTR)UL1TR000445 · NCATS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI BERNARD, GORDON RAPHAEL · 2012 to 2016
$41.4M
Shop Module CoreP30EY008126 · NEI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI Kevin L Schey · 1989 to 2026
$19.6M
Training in Vision ResearchT32EY007135 · NEI · VANDERBILT UNIVERSITY · PI GEOFFREY F WOODMAN · 1994 to 2026
$5.8M
Microstructural Characterization of the Optic Nerve in Optic NeuritisR01EY023240 · NEI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI SMITH, SETH A · 2014 to 2017
$1.0M
Quantitative Image Analysis Techniques for Optic Nerve DiseaseR21EY024036 · NEI · VANDERBILT UNIVERSITY · PI LANDMAN, BENNETT A. · 2014 to 2015
$410k
NCATS NIH HHS UL1 TR000445NCRR NIH HHS UL1 RR024975NEI NIH HHS P30 EY008126NEI NIH HHS R01 EY023240NEI NIH HHS R21 EY024036NEI NIH HHS T32 EY007135
6 · The paper itself

Abstract

The optic nerve (ON) is a vital structure in the human visual system and transports all visual information from the retina to the cortex for higher order processing. Due to the lack of redundancy in the visual pathway, measures of ON damage have been shown to correlate well with visual deficits. These measures are typically taken at an arbitrary anatomically defined point along the nerve and do not characterize changes along the length of the ON. We propose a fully automated, three-dimensionally consistent technique building upon a previous independent slice-wise technique to estimate the radius of the ON and surrounding cerebrospinal fluid (CSF) on high-resolution heavily T2-weighted isotropic MRI. We show that by constraining results to be three-dimensionally consistent this technique produces more anatomically viable results. We compare this technique with the previously published slice-wise technique using a short-term reproducibility data set, 10 subjects, follow-up <1 month, and show that the new method is more reproducible in the center of the ON. The center of the ON contains the most accurate imaging because it lacks confounders such as motion and frontal lobe interference. Long-term reproducibility, 5 subjects, follow-up of approximately 11 months, is also investigated with this new technique and shown to be similar to short-term reproducibility, indicating that the ON does not change substantially within 11 months. The increased accuracy of this new technique provides increased power when searching for anatomical changes in ON size amongst patient populations.

Indexed as

Conjugate Gradient DescentIntensity Model FittingMagnetic Resonance ImagingOptic Nerve

Identifiers

PMID28736469
PMCPMC5521273
OpenAlexW2593235561

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.