ArticleLa Radiologia medica2017

Feasibility of optimized ultralow-dose pulsed fluoroscopy for upper gastrointestinal tract examinations: a phantom study with clinical correlation.

Jakob Weiss, Andreas Pomschar, Carsten Rist, Klement Neumaier, Minglun Li, Wilhelm Flatz, Kolja Thierfelder, Mike Notohamiprodjo

Abstract read
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 88% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Jakob WeissDepartment of Diagnostic and Interventional Radiology, Eberhard-Karls-University, University of Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tuebingen, Germany. Jakob.Weiss@med.uni-tuebingen.de.
Andreas PomscharDepartment of Diagnostic and Interventional Radiology, Ludwig-Maximilians-University Munich, Marchioninistr. 15, 81377, Munich, Germany.
Carsten RistDepartment of Diagnostic and Interventional Radiology, Ludwig-Maximilians-University Munich, Marchioninistr. 15, 81377, Munich, Germany.
Klement NeumaierDepartment of Radiooncology and Radiotherapy, Ludwig-Maximilians-University Munich, Marchioninistr. 15, 81377, Munich, Germany.
Minglun LiDepartment of Radiooncology and Radiotherapy, Ludwig-Maximilians-University Munich, Marchioninistr. 15, 81377, Munich, Germany.
Wilhelm FlatzDepartment of Diagnostic and Interventional Radiology, Ludwig-Maximilians-University Munich, Marchioninistr. 15, 81377, Munich, Germany.
Kolja ThierfelderDepartment of Diagnostic and Interventional Radiology, Ludwig-Maximilians-University Munich, Marchioninistr. 15, 81377, Munich, Germany.
Mike NotohamiprodjoDepartment of Diagnostic and Interventional Radiology, Eberhard-Karls-University, University of Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tuebingen, Germany.
Ludwig-Maximilians-Universität München · DEUniversity of Tübingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo establish an optimized ultralow-dose digital pulsed fluoroscopy (FP) protocol for upper gastrointestinal tract examinations and to investigate the radiation dose and image quality. MATERIALS AND

methodsAn Alderson-Rando-Phantom with 60 thermoluminescent dosimeters was used for dose measurements to systematically evaluate the dose-area product (DAP) and organ doses of the optimized FP protocol with the following acquisition parameters: 86.7 kV; 77 mA; 0.9 mm

resultsPhantom measurements revealed a general dose reduction of approximately 96% per image for the FP protocol as compared to the DR standard. DAP could be reduced by 97%. Significant dose reductions were also found for organ doses, both in the direct and scattered radiation beam with negligible orbital (FP 5.6 × 10

conclusionUltralow-dose FP is feasible for clinical routine allowing a significant reduction of direct and scattered dose exposure while providing sufficient diagnostic image quality for reliable diagnosis.

Indexed as

AdultAgedAged, 80 and overContrast MediaFemaleFluoroscopyHumansMaleMiddle AgedPhantoms, ImagingRadiation DosageRetrospective StudiesThermoluminescent DosimetryUpper Gastrointestinal TractContrast MediaAbdomenGastrointestinal imagingTechnical evaluationUltralow-dose fluoroscopy

Identifiers

PMID28733918
OpenAlexW2738901128

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.