Evidence map›Paper›PMID 28725970›Full record

ArticleInternational orthopaedics2018

Ion release in ceramic bearings for total hip replacement: Results from an in vitro and an in vivo study.

Jan Philippe Kretzer, Ulrike Mueller, Marcus R Streit, Hartmuth Kiefer, Robert Sonntag, Robert M Streicher, Joern Reinders

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Metallic Implants Used in Lumbar Interbody Fusion.Materials (Basel, Switzerland) · 2022
    Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Jan Philippe KretzerLaboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. philippe.kretzer@med.uni-heidelberg.de.
Ulrike MuellerLaboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
Marcus R StreitLaboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
Hartmuth KieferClinic for Trauma and Orthopaedic Surgery, Hand and Reconstructive Surgery, Joint Center, 32257, Buende, Germany.
Robert SonntagLaboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
Robert M StreicherDr. Streicher GmbH, 8835, Feusisberg, Switzerland.
Joern ReindersLaboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
Heidelberg University · DEUniversity Hospital Heidelberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionLiterature on the potential release of trace elements following implantation of Zirconia-platelet toughened alumina (ZPTA) ceramic components is scant. The present study therefore analysed the in vitro and in vivo potential release of ions from ZPTA bearings. MATERIAL AND

methodsAn in vitro and in vivo study was conducted. The in vitro study compared leaching in bovine serum from two groups: ZPTA ceramic heads and Co-28Cr-6Mo alloy heads, both 28-mm diameter. A third group without implant served as reference group. An in vivo clinical study compared trace elements in the whole blood of patients with 36-mm diameter ZPTA ceramic-on-ceramic articulation after three and 12 months. A cohort of subjects without any prosthesis was used as control group. The release of ions was determined by high resolution-inductively coupled plasma-mass spectrometry.

resultsIn the in vitro experiment, significant differences (p ≤ 0.01) in trace element release for chromium, cobalt and molybdenum were found, with increased levels of ion release in the Co-28Cr-6Mo metal group. The very low detection limit for yttrium allowed detection of a small yttrium release from the ZPTA heads, which was not confirmed by the in vivo study. No significant difference between the groups was found for strontium, aluminium, and zirconium. In the in vivo study, no relevant differences in ion levels between the reference group without any implant and the study group were found at the three and 12-month follow-up.

conclusionThis study supports that ZPTA ceramic articulation components are safe in terms of ion release, and may be an excellent alternative to bearings based on Co-28Cr-6Mo alloys.

Indexed as

AdultAgedAlloysAnimalsArthroplasty, Replacement, HipCattleCeramicsFemaleHip ProsthesisHumansIonsMaleMass SpectrometryMiddle AgedProsthesis DesignTrace ElementsAlloysIonsTrace ElementsZirconiumCeramicsMetal ionsStabilityTotal hip arthroplastyTribology

Identifiers

PMID28725970
OpenAlexW2738230083

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.