ArticleScientific reports2017
Interferometric rotating point spread function.
Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Fused deep learning enables 6D single-molecule localization in polarization-resolved microscopy.Methods and applications in fluorescence · 2026Article
- Three-dimensional tracking using a single-spot rotating point spread function created by a multiring spiral phase plate.Journal of biomedical optics · 2022Article
- Three-Dimensional Incoherent Imaging Using Spiral Rotating Point Spread Functions Created by Double-Helix Beams [Invited].Nanoscale research letters · 2022Article
Corrections and comments
- Erratum issued
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Rotating point spread functions (PSF), such as the double helix (DH) PSF, are widely used in localization-based super-resolution imaging because of their large working depth range. In this article, we propose an interferometric DH PSF (iDH PSF) using two opposed objective lenses as in the 4Pi microscope. In the proposed iDH PSF, the super-resolution in the axial PSF is transferred to the azimuthal rotation. Moreover, we design an iDH PSF whose imaging range reaches 3 μm, which is roughly 3 times as much as that which can be obtained by using other interferometric localization-based super-resolution imaging methods.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.