Evidence map›Paper›PMID 28724628›Full record

ArticleJournal of the Royal Society, Interface2017

Stiffness distribution in insect cuticle: a continuous or a discontinuous profile?

H Rajabi, M Jafarpour, A Darvizeh, J-H Dirks, S N Gorb

Abstract read
In one paragraph

Article in Journal of the Royal Society, Interface, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Wing Coupling in Bees and Wasps: From the Underlying Science to Bioinspired Engineering.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

H RajabiInstitute of Zoology, Functional Morphology and Biomechanics, Kiel University, Kiel, Germany hrajabi@zoologie.uni-kiel.de harajabi@hotmail.com.ORCID 0000-0002-1792-3325
M JafarpourDepartment of Mechanical Engineering, University of Guilan, Rasht, Iran.
A DarvizehDepartment of Mechanical Engineering, University of Guilan, Rasht, Iran.
J-H DirksBiomimetics-Innovation-Centre, Bremen University of Applied Sciences, Bremen, Germany.
S N GorbInstitute of Zoology, Functional Morphology and Biomechanics, Kiel University, Kiel, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Insect cuticle is a biological composite with a high degree of complexity in terms of both architecture and material composition. Given the complex morphology of many insect body parts, finite-element (FE) models play an important role in the analysis and interpretation of biomechanical measurements, taken by either macroscopic or nanoscopic techniques. Many previous studies show that the interpretation of nanoindentation measurements of this layered composite material is very challenging. To develop accurate FE models, it is of particular interest to understand more about the variations in the stiffness through the thickness of the cuticle. Considering the difficulties of making direct measurements, in this study, we use the FE method to analyse previously published data and address this issue numerically. For this purpose, sets of continuous or discontinuous stiffness profiles through the thickness of the cuticle were mathematically described. The obtained profiles were assigned to models developed based on the cuticle of three insect species with different geometries and layer configurations. The models were then used to simulate the mechanical behaviour of insect cuticles subjected to nanoindentation experiments. Our results show that FE models with discontinuous exponential stiffness gradients along their thickness were able to predict the stress and deformation states in insect cuticle very well. Our results further suggest that, for more accurate measurements and interpretation of nanoindentation test data, the ratio of the indentation depth to cuticle thickness should be limited to 7% rather than the traditional '10% rule'. The results of this study thus might be useful to provide a deeper insight into the biomechanical consequences of the distinct material distribution in insect cuticle and also to form a basis for more realistic modelling of this complex natural composite.

Indexed as

AnimalsBiomechanical PhenomenaInsectaIntegumentary SystemModels, Biologicalfinite-element methodinsect cuticlematerial gradientmechanical behaviournanoindentation

Identifiers

PMID28724628
PMCPMC5550976

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.