ArticleClinical orthopaedics and related research2017
High Survivorship and Few Complications With Cementless Total Wrist Arthroplasty at a Mean Followup of 9 Years.
Article in Clinical orthopaedics and related research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 40 citations in OpenAlex.
- Total wrist arthroplasty efficacy and safety: a systematic review.Journal of orthopaedics · 2026Review
- Failure of Universal 2 Wrist Joint Replacements: A Retrieval Study.Journal of wrist surgery · 2026Article
- Comment: Intermediate and Long-Term Outcomes of the Universal 2 Total Wrist Replacement.Journal of wrist surgery · 2025Article
- Intermediate and Long-Term Outcomes of the Universal 2 Total Wrist Replacement.Journal of wrist surgery · 2024Article
- Artificial intelligence-based three-dimensional templating for total joint arthroplasty planning: a scoping review.International orthopaedics · 2024Article
- The Effect of Locking Screws on Distal Component Fixation in Total Wrist Arthroplasty Using a Cadaver Model.Journal of hand surgery global online · 2022Article
- Fourth-Generation Total Wrist Arthroplasty: A Systematic Review of Clinical Outcomes.Journal of wrist surgery · 2022Article
- Correlation between carpal rotational alignment and postoperative wrist range of motion following total wrist arthroplasty.BMC musculoskeletal disorders · 2022Article
- Total Wrist Arthroplasty-A Systematic Review of the Outcome, and an Introduction of FreeMove-An Approach to Improve TWA.Life (Basel, Switzerland) · 2022Review
- Medium-Term Outcomes for Amandys Implant: A 5-Year Minimum Follow-Up of 63 Cases.Journal of wrist surgery · 2022Article
- Total Wrist Arthroplasty Alignment and Its Potential Association with Clinical Outcomes.Journal of wrist surgery · 2021Article
- Long-Term Results of the Modular Physiological Wrist Prosthesis (MPWLife (Basel, Switzerland) · 2021Article
- Proximal-distal shift of the center of rotation in a total wrist arthroplasty is more than twice of the healthy wrist.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2020Article
- Resurfacing capitate pyrocarbon implant after proximal row carpectomy: A litterature review.Orthopedic reviews · 2020Article
- Acute Complications in Total Wrist Arthroplasty: A National Surgical Quality Improvement Program Review.Journal of wrist surgery · 2020Article
- [Total wrist arthroplasty-a review].Der Orthopade · 2019Review
- Systematic Review of Total Wrist Arthroplasty and Arthrodesis in Wrist Arthritis.Journal of wrist surgery · 2018Article
- [Complications in orthopedic rheumatology-characteristics of operative procedures].Der Orthopade · 2018Review
Corrections and comments
- Commented on byCORR Insights2017
Authors and funding
4 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTotal wrist arthroplasty (TWA) has been described as traditionally being performed with fixation in the radius and carpus with cement. The TWA implant used in our series has been associated with promising results in studies with up to 6 years followup; however, studies evaluating survivorship, pain, and function with this implant are limited. QUESTION/PURPOSE: (1) To report ROM and pain scores after wrist reconstruction with cementless fourth-generation TWA at a mean followup of 9 years (range, 4.8-14.7 years). (2) To report complications of a cementless fourth-generation TWA and the cumulative probability of not undergoing a revision at a mean followup of 9 years.
methodsThis is a retrospective case series of 69 patients who were treated for pancarpal wrist arthritis between 2002 and 2014. Of those, 31 had inflammatory arthritis (rheumatoid arthritis [n = 29], juvenile rheumatoid arthritis [n = 1], and psoriatic arthritis [n = 1]); all of these patients received TWA with the cementless implant studied in this investigation. Another 38 patients had osteoarthritis or posttraumatic arthritis; in this subgroup, 28 patients were 65 years or younger, and all underwent wrist fusion (none were offered TWA). Ten patients with osteoarthritis were older than 65 years and all were offered TWA; of those, eight underwent TWA, and two declined the procedure and instead preferred and underwent total wrist arthrodesis. The mean age of the 39 patients who had TWA was 56 ± 8.9 years (range, 31-78 years) at the time of surgery; 36 were women and three were men. The patients who underwent TWA were seen at a minimum of 4 years (mean, 9 years; range, 4-15 years), and all had been examined in 2016 as part of this study except for one patient who died 9 years after surgery. The dominant wrist was involved in 60% (25) of the patients. All patients were immobilized for 4 weeks postoperatively and then underwent hand therapy for 4 to 6 weeks. Pain and ROM were gathered before surgery as part of clinical care, and were measured again at latest followup; at latest followup, radiographs were analyzed (by the senior author) for evidence of loosening, defined as any implant migration compared with any previous radiograph with evidence of periimplant osteolysis and bone resorption. Subjective pain score was assessed by a verbal pain scale (0-10) and ROM was measured with a goniometer. Complications were determined by chart review and final examination. Kaplan Meier survival analysis was performed to estimate the cumulative probability of not undergoing a revision.
resultsThe mean preoperative active ROM was 34
conclusionCementless fourth-generation TWA improves pain while generally preserving the preoperative arc of motion. The cumulative probability of remaining free from revision at 14.7 years after the index procedure is 77.7% (95% CI, 62.0%-91.4%). Future studies should compare alternative approaches for patients with endstage wrist arthritis; such evaluations-which might compare TWA implants, or TWAs with arthrodesis-will almost certainly need to be multicenter, as the problem is relatively uncommon. LEVEL OF EVIDENCE: Level IV, therapeutic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.