Evidence map›Paper›PMID 28719441›Full record

ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)

Fourteen Day In Vivo Testing of a Compliant Thoracic Artificial Lung.

David J Skoog, Joshua R Pohlmann, David S Demos, Christopher N Scipione, Amit Iyengar, Rebecca E Schewe, Ahmed B Suhaib, Kelly L Koch, Keith E Cook

Open access · greenAbstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Article
  3. Hemocompatibility Evaluation of a Novel Ambulatory Pulmonary Assist System Using a Lightweight Axial-Flow Pump.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2024
    Article
  4. Article
  5. Ambulatory 7-day mechanical circulatory support in sheep model of pulmonary hypertension and right heart failure.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2024
    Article
  6. Article
  7. Article
  8. A Model of Pediatric End-Stage Lung Failure in Small Lambs <20 kg.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2020
    Article
  9. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

David J SkoogFrom the *Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan; †Department of Surgery, University of Michigan, Ann Arbor, Michigan; and ‡Department of General Surgery, Henry Ford Health System, Detroit, Michigan.
Joshua R Pohlmann
David S Demos
Christopher N Scipione
Amit Iyengar
Rebecca E Schewe
Ahmed B Suhaib
Kelly L Koch
Keith E Cook
Henry Ford Health System · USUniversity of Michigan–Ann Arbor · US

Funding

Compliant Thoracic Artificial LungsR01HL089043 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI COOK, KEITH E · 2009 to 2017
$4.2M
NHLBI NIH HHS R01 HL089043
6 · The paper itself

Abstract

The compliant thoracic artificial lung (cTAL) has been studied in acute in vivo and in vitro experiments. The cTAL's long-term function and potential use as a bridge to lung transplantation are assessed presently. The cTAL without anticoagulant coatings was attached to sheep (n = 5) via the pulmonary artery and left atrium for 14 days. Systemic heparin anticoagulation was used. Compliant thoracic artificial lung resistance, cTAL gas exchange, hematologic parameters, and organ function were recorded. Two sheep were euthanized for nondevice-related issues. The cTAL's resistance averaged 1.04 ± 0.05 mmHg/(L/min) with no statistically significant increases. The cTAL transferred 180 ± 8 ml/min of oxygen with 3.18 ± 0.05 L/min of blood flow. Except for transient surgical effects, organ function markers were largely unchanged. Necropsies revealed pulmonary edema and atelectasis but no other derangements. Hemoglobin levels dropped with device attachment but remained steady at 9.0 ± 0.1 g/dl thereafter. In a 14 day experiment, the cTAL without anticoagulant coatings exhibited minimal clot formation. Sheep physiology was largely unchanged except for device attachment-related hemodilution. This suggests that patients treated with the cTAL should not require multiple blood transfusions. Once tested with anticoagulant coatings and plasma resistant gas exchange fiber, the cTAL could serve as a bridge to transplantation.

Indexed as

Artificial OrgansLungAnimalsAnticoagulantsExtracorporeal Membrane OxygenationLung TransplantationOxygenPulmonary Gas ExchangeSheepAnticoagulantsOxygen

Identifiers

PMID28719441
PMCPMC5788287
OpenAlexW2737864164

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.