Evidence map›Paper›PMID 28716018›Full record

Observational studyBMC pediatrics2017

Prediction of Extubation readiness in extremely preterm infants by the automated analysis of cardiorespiratory behavior: study protocol.

Wissam Shalish, Lara J Kanbar, Smita Rao, Carlos A Robles-Rubio, Lajos Kovacs, Sanjay Chawla, Martin Keszler, Doina Precup, Karen Brown, Robert E Kearney and 1 more

Registry-linked trialOpen access · goldAbstract readMulticenter StudyObservational Study
In one paragraph

Observational study in BMC pediatrics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01909947 (Prediction of Extubation Readiness in Extreme Preterm Infants by the Automated Analysis of CardioRespiratory Behavior), which is not on this map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01909947 completednot on this map

Prediction of Extubation Readiness in Extreme Preterm Infants by the Automated Analysis of CardioRespiratory Behavior: the APEX Study

TypeobservationalSponsorMcGill University Health Centre/Research Institute of the McGill University Health CentreRan2013 to 2018Enrolled266ConditionsPrediction of Extubation ReadinessArmsCardiorespiratory signal acquisition
3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it, 48 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Accuracy of lung ultrasound in predicting successful extubation in preterm infants born ≤ 25 weeks.Journal of perinatology : official journal of the California Perinatal Association · 2025
    Article
  4. Review
  5. Observational
  6. Article
  7. Review
  8. Article
  9. Prediction of extubation failure among low birthweight neonates using machine learning.Journal of perinatology : official journal of the California Perinatal Association · 2023
    Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Observational
  17. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 2 countries.

Wissam ShalishDepartment of Pediatrics, Division of Neonatology, Montreal Children's Hospital, McGill University, 1001 Boul. Décarie, room B05.2714. Montreal, Quebec, H4A 3J1, Canada.
Lara J KanbarDepartment of Biomedical Engineering, McGill University, Montreal, Quebec, H3A 2B4, Canada.
Smita RaoDepartment of Pediatrics, Division of Neonatology, Montreal Children's Hospital, McGill University, 1001 Boul. Décarie, room B05.2714. Montreal, Quebec, H4A 3J1, Canada.
Carlos A Robles-RubioDepartment of Biomedical Engineering, McGill University, Montreal, Quebec, H3A 2B4, Canada.
Lajos KovacsDepartment of Neonatology, Jewish General Hospital, Montreal, Quebec, H3T 1E2, Canada.
Sanjay ChawlaDivision of Neonatal-Perinatal Medicine, Hutzel Women's Hospital, Wayne State University, Detroit, MI, 48201, USA.
Martin KeszlerDepartment of Pediatrics, Women and Infants Hospital of Rhode Island, Brown University, Providence, RI, 02905, USA.
Doina PrecupDepartment of Computer Science, McGill University, Montreal, Quebec, H3A 0E9, Canada.
Karen BrownDepartment of Anesthesia, Montreal Children's Hospital, McGill University Health Center, Montreal, Quebec, H4A 3J1, Canada.
Robert E KearneyDepartment of Biomedical Engineering, McGill University, Montreal, Quebec, H3A 2B4, Canada.
Guilherme M Sant'AnnaDepartment of Pediatrics, Division of Neonatology, Montreal Children's Hospital, McGill University, 1001 Boul. Décarie, room B05.2714. Montreal, Quebec, H4A 3J1, Canada. guilherme.santanna@mcgill.ca.
McGill University · CAHutzel Women's Hospital · USJewish General Hospital · CAMontreal Children's Hospital · CAWomen & Infants Hospital of Rhode Island · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExtremely preterm infants (≤ 28 weeks gestation) commonly require endotracheal intubation and mechanical ventilation (MV) to maintain adequate oxygenation and gas exchange. Given that MV is independently associated with important adverse outcomes, efforts should be made to limit its duration. However, current methods for determining extubation readiness are inaccurate and a significant number of infants fail extubation and require reintubation, an intervention that may be associated with increased morbidities. A variety of objective measures have been proposed to better define the optimal time for extubation, but none have proven clinically useful. In a pilot study, investigators from this group have shown promising results from sophisticated, automated analyses of cardiorespiratory signals as a predictor of extubation readiness. The aim of this study is to develop an automated predictor of extubation readiness using a combination of clinical tools along with novel and automated measures of cardiorespiratory behavior, to assist clinicians in determining when extremely preterm infants are ready for extubation.

methodsIn this prospective, multicenter observational study, cardiorespiratory signals will be recorded from 250 eligible extremely preterm infants with birth weights ≤1250 g immediately prior to their first planned extubation. Automated signal analysis algorithms will compute a variety of metrics for each infant, and machine learning methods will then be used to find the optimal combination of these metrics together with clinical variables that provide the best overall prediction of extubation readiness. Using these results, investigators will develop an Automated system for Prediction of EXtubation (APEX) readiness that will integrate the software for data acquisition, signal analysis, and outcome prediction into a single application suitable for use by medical personnel in the neonatal intensive care unit. The performance of APEX will later be prospectively validated in 50 additional infants. DISCUSSION: The results of this research will provide the quantitative evidence needed to assist clinicians in determining when to extubate a preterm infant with the highest probability of success, and could produce significant improvements in extubation outcomes in this population.

trial registrationClinicaltrials.gov identifier: NCT01909947 . Registered on July 17 2013. Trial sponsor: Canadian Institutes of Health Research (CIHR).

Indexed as

AlgorithmsDecision Support TechniquesAirway ExtubationClinical Decision-MakingClinical ProtocolsHeart RateHumansInfant, Extremely PrematureInfant, NewbornProspective StudiesRespiration, ArtificialRespiratory RateBiomedical signal processingCardiorespiratory behaviorClinical predictorsExtubation readinessHeart rate variabilityRespiratory variability

Identifiers

PMID28716018
PMCPMC5512825
OpenAlexW2735429711

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.