Observational studyBMC pediatrics2017
Prediction of Extubation readiness in extremely preterm infants by the automated analysis of cardiorespiratory behavior: study protocol.
Observational study in BMC pediatrics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01909947 (Prediction of Extubation Readiness in Extreme Preterm Infants by the Automated Analysis of CardioRespiratory Behavior), which is not on this map. Cited by 17 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Prediction of Extubation Readiness in Extreme Preterm Infants by the Automated Analysis of CardioRespiratory Behavior: the APEX Study
Who cites it
17 citing papers in PubMed, 1 synthesis or guideline pooled it, 48 citations in OpenAlex.
- Opportunities and Challenges of Using Artificial Intelligence in Predicting Clinical Outcomes and Length of Stay in Neonatal Intensive Care Units: Systematic Review.Journal of medical Internet research · 2025Pooled it
- Predicting failure of extubation and non-invasive respiratory support in critically ill patients: clinical complexity, limitations of traditional indices, and machine learning perspectives.Frontiers in medicine · 2026Review
- Accuracy of lung ultrasound in predicting successful extubation in preterm infants born ≤ 25 weeks.Journal of perinatology : official journal of the California Perinatal Association · 2025Article
- Oxycardiorespirograms in neonatal monitoring-current gaps and future potential of artificial intelligence: a mini-review.Frontiers in pediatrics · 2025Review
- Predicting Extubation Readiness in Preterm Infants Utilizing Machine Learning: A Diagnostic Utility Study.The Journal of pediatrics · 2024Observational
- Using machine-learning models to predict extubation failure in neonates with bronchopulmonary dysplasia.BMC pulmonary medicine · 2024Article
- The past, current, and future of neonatal intensive care units with artificial intelligence: a systematic review.NPJ digital medicine · 2023Review
- Automated prediction of extubation success in extremely preterm infants: the APEX multicenter study.Pediatric research · 2023Article
- Prediction of extubation failure among low birthweight neonates using machine learning.Journal of perinatology : official journal of the California Perinatal Association · 2023Article
- Weaning and extubation from neonatal mechanical ventilation: an evidenced-based review.BMC pulmonary medicine · 2022Review
- Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial.Annals of medicine and surgery (2012) · 2022Article
- Can Fraction of Inspired Oxygen Predict Extubation Failure in Preterm Infants?Children (Basel, Switzerland) · 2022Article
- Accuracy of Spontaneous Breathing Trial Using ET-CPAP in Predicting Successful Extubation of Neonates.Cureus · 2021Article
- Diaphragmatic activity and neural breathing variability during a 5-min endotracheal continuous positive airway pressure trial in extremely preterm infants.Pediatric research · 2021Article
- Assessment of Extubation Readiness Using Spontaneous Breathing Trials in Extremely Preterm Neonates.JAMA pediatrics · 2020Article
- Patterns of reintubation in extremely preterm infants: a longitudinal cohort study.Pediatric research · 2018Observational
- Extubation in the pediatric intensive care unit: predictive methods. An integrative literature review.Revista Brasileira de terapia intensivaReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundExtremely preterm infants (≤ 28 weeks gestation) commonly require endotracheal intubation and mechanical ventilation (MV) to maintain adequate oxygenation and gas exchange. Given that MV is independently associated with important adverse outcomes, efforts should be made to limit its duration. However, current methods for determining extubation readiness are inaccurate and a significant number of infants fail extubation and require reintubation, an intervention that may be associated with increased morbidities. A variety of objective measures have been proposed to better define the optimal time for extubation, but none have proven clinically useful. In a pilot study, investigators from this group have shown promising results from sophisticated, automated analyses of cardiorespiratory signals as a predictor of extubation readiness. The aim of this study is to develop an automated predictor of extubation readiness using a combination of clinical tools along with novel and automated measures of cardiorespiratory behavior, to assist clinicians in determining when extremely preterm infants are ready for extubation.
methodsIn this prospective, multicenter observational study, cardiorespiratory signals will be recorded from 250 eligible extremely preterm infants with birth weights ≤1250 g immediately prior to their first planned extubation. Automated signal analysis algorithms will compute a variety of metrics for each infant, and machine learning methods will then be used to find the optimal combination of these metrics together with clinical variables that provide the best overall prediction of extubation readiness. Using these results, investigators will develop an Automated system for Prediction of EXtubation (APEX) readiness that will integrate the software for data acquisition, signal analysis, and outcome prediction into a single application suitable for use by medical personnel in the neonatal intensive care unit. The performance of APEX will later be prospectively validated in 50 additional infants. DISCUSSION: The results of this research will provide the quantitative evidence needed to assist clinicians in determining when to extubate a preterm infant with the highest probability of success, and could produce significant improvements in extubation outcomes in this population.
trial registrationClinicaltrials.gov identifier: NCT01909947 . Registered on July 17 2013. Trial sponsor: Canadian Institutes of Health Research (CIHR).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.