Evidence map›Paper›PMID 28712286›Full record

ArticleJournal of the American Chemical Society2017

Calibration-Free Electrochemical Biosensors Supporting Accurate Molecular Measurements Directly in Undiluted Whole Blood.

Hui Li, Philippe Dauphin-Ducharme, Gabriel Ortega, Kevin W Plaxco

Open access · greenAbstract read
In one paragraph

Article in Journal of the American Chemical Society, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 69 papers.

0numbers the graph read from it
0cells of the map it votes in
69citing papers in PubMed
7.3field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

69 citing papers in PubMed, 218 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Bioelectronics forNanotheranostics · 2026
    Review
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Review
  19. Article
  20. Article

9 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 3 countries.

Hui LiFaculty of Materials Science and Chemistry, China University of Geosciences , Wuhan 430074, China.ORCID 0000-0001-7849-9735
Philippe Dauphin-DucharmeDepartment of Chemistry and Biochemistry, University of California Santa Barbara , Santa Barbara, California 93106, United States.ORCID 0000-0002-0490-7115
Gabriel OrtegaDepartment of Chemistry and Biochemistry, University of California Santa Barbara , Santa Barbara, California 93106, United States.
Kevin W PlaxcoDepartment of Chemistry and Biochemistry, University of California Santa Barbara , Santa Barbara, California 93106, United States.ORCID 0000-0003-4772-8771
University of California, Santa Barbara · US

Funding

A new approach to quantitative, point-of-care serologyR01AI107936 · NIAID · UNIVERSITY OF CALIFORNIA SANTA BARBARA · PI PLAXCO, KEVIN W · 2014 to 2017
$1.4M
NIAID NIH HHS R01 AI107936
6 · The paper itself

Abstract

The need to calibrate to correct for sensor-to-sensor fabrication variation and sensor drift has proven a significant hurdle in the widespread use of biosensors. To maintain clinically relevant (±20% for this application) accuracy, for example, commercial continuous glucose monitors require recalibration several times a day, decreasing convenience and increasing the chance of user errors. Here, however, we demonstrate a "dual-frequency" approach for achieving the calibration-free operation of electrochemical biosensors that generate an output by using square-wave voltammetry to monitor binding-induced changes in electron transfer kinetics. Specifically, we use the square-wave frequency dependence of their response to produce a ratiometric signal, the ratio of peak currents collected at responsive and non- (or low) responsive square-wave frequencies, which is largely insensitive to drift and sensor-to-sensor fabrication variations. Using electrochemical aptamer-based (E-AB) biosensors as our test bed, we demonstrate the accurate and precise operation of sensors against multiple drugs, achieving accuracy in the measurement of their targets of within better than 20% across dynamic ranges of up to 2 orders of magnitude without the need to calibrate each individual sensor.

Indexed as

Anesthetics, LocalAnti-Bacterial AgentsAntibiotics, AntineoplasticAptamers, NucleotideBiosensing TechniquesCalibrationCocaineDoxorubicinElectrochemical TechniquesHumansKanamycinPharmaceutical PreparationsAnesthetics, LocalAnti-Bacterial AgentsAntibiotics, AntineoplasticAptamers, NucleotideCocaineDoxorubicinKanamycinPharmaceutical Preparations

Identifiers

PMID28712286
PMCPMC6519131
OpenAlexW2734822630

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked