Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation.

Qeumars Mustafa Hamie, Adrian Raoul Kobe, Leif Mietzsch, Michael Manhart, Gilbert Dominique Puippe, Thomas Pfammatter, Roman Guggenberger

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Qeumars Mustafa HamieDepartment of Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Adrian Raoul KobeDepartment of Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Leif MietzschDepartment of Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Michael ManhartSiemens Healthcare GmbH, Advanced Therapies, Innovation, Imaging Concepts, HC AT IN IMC, Simon-Hegele-Str. 1, 91301, Forchheim, Deutschland.
Gilbert Dominique PuippeDepartment of Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Thomas PfammatterDepartment of Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Roman GuggenbergerDepartment of Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland. roman.guggenberger@usz.ch.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. METHODS AND MATERIALS: Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared

resultsQuantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters.

conclusionIn patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. KEY POINTS: • Metal objects cause artefacts in cone-beam computed tomography (CBCT) imaging. • These artefacts can be corrected by metal artefact reduction (MAR) algorithms. • Corrected images show significantly better visibility of nearby hepatic vessels and tissue. • Better visibility may facilitate image interpretation, save time and radiation exposure.

Indexed as

AlgorithmsArtifactsAdultAgedAged, 80 and overAngiographyCone-Beam Computed TomographyFemaleHumansImage Processing, Computer-AssistedLiverLiver NeoplasmsMaleMetalsMiddle AgedRetrospective StudiesMetalsAbdomenCone-beam computed tomographyLiverMetal artefact reductionTransarterial radioembolisation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.