ArticlePloS one2017
Performance characteristics of finger-stick dried blood spots (DBS) on the determination of human immunodeficiency virus (HIV) treatment failure in a pediatric population in Mozambique.
Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- The plasma separation card as a novel solution for enhancing central laboratory capability for HIV-1 viral load monitoring in limited-access settings.PLOS global public health · 2023Article
- Stability of HIV-1 Nucleic Acids in cobas Plasma Separation Card for Viral Load Measurement.American journal of clinical pathology · 2022Article
- Validation of mailedGlobal health & medicine · 2021Article
- Article
- Accurate HIV viral load measurement in primary health care settings using the cobas® plasma separation card.PloS one · 2020Article
- Field Suitability and Diagnostic Accuracy of the Biocentric Open Real-Time PCR Platform for Dried Blood Spot-Based HIV Viral Load Quantification in Eswatini.Journal of acquired immune deficiency syndromes (1999) · 2019Article
- Separation of Plasma from Whole Blood by Use of the cobas Plasma Separation Card: a Compelling Alternative to Dried Blood Spots for Quantification of HIV-1 Viral Load.Journal of clinical microbiology · 2019Article
- Dried Blood Spots for Global Health Diagnostics and Surveillance: Opportunities and Challenges.The American journal of tropical medicine and hygiene · 2018Review
- Adherence Measurements in HIV: New Advancements in Pharmacologic Methods and Real-Time Monitoring.Current HIV/AIDS reports · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Quantitative plasma viral load (VL) at 1000 copies /mL was recommended as the threshold to confirm antiretroviral therapy (ART) failure by the World Health Organization (WHO). Because of ongoing challenges of using plasma for VL testing in resource-limited settings (RLS), especially for children, this study collected 717 DBS and paired plasma samples from children receiving ART ≥1 year in Mozambique and compared the performance of DBS using Abbott's VL test with a paired plasma sample using Roche's VL test. At a cut-off of 1000 copies/mL, sensitivity of DBS using Abbott DBS VL test was 79.9%, better than 71.0% and 63.9% at 3000 and 5000 copies/mL, respectively. Specificities were 97.6%, 98.8%, 99.3% at 1000, 3000, and 5000 copies/mL, respectively. The Kappa value at 1000 copies/mL, 0.80 (95% CI: 0.73, 0.87), was higher than 0.73 (95% CI: 0.66, 0.80) and 0.66 (95% CI: 0.59, 0.73) at 3000, 5000 copies/mL, respectively, also indicating better agreement. The mean difference between the DBS and plasma VL tests with 95% limits of agreement by Bland-Altman was 0.311 (-0.908, 1.530). Among 73 children with plasma VL between 1000 to 5000 copies/mL, the DBS results were undetectable in 53 at the 1000 copies/mL threshold. While one DBS sample in the Abbott DBS VL test may be an alternative method to confirm ART failure at 1000 copies/mL threshold when a plasma sample is not an option for treatment monitoring, because of sensitivity concerns between 1,000 and 5,000 copies/ml, two DBS samples may be preferred accompanied by careful patient monitoring and repeat testing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.