A novel and independent method for time-resolved gantry angle quality assurance for VMAT.

Todsaporn Fuangrod, Peter B Greer, Benjamin J Zwan, Michael P Barnes, Joerg Lehmann

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Todsaporn FuangrodDepartment of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.
Peter B GreerDepartment of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.
Benjamin J ZwanSchool of Mathematical and Physics Sciences, Faculty of Science and IT, the University of Newcastle, Newcastle, NSW, Australia.
Michael P BarnesDepartment of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.
Joerg LehmannDepartment of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.
Calvary Mater Newcastle Hospital · AUUniversity of Newcastle Australia · AUGosford Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Volumetric-modulated arc therapy (VMAT) treatment delivery requires three key dynamic components; gantry rotation, dose rate modulation, and multi-leaf collimator motion, which are all simultaneously varied during the delivery. Misalignment of the gantry angle can potentially affect clinical outcome due to the steep dose gradients and complex MLC shapes involved. It is essential to develop independent gantry angle quality assurance (QA) appropriate to VMAT that can be performed simultaneously with other key VMAT QA testing. In this work, a simple and inexpensive fully independent gantry angle measurement methodology was developed that allows quantitation of the gantry angle accuracy as a function of time. This method is based on the analysis of video footage of a "Double dot" pattern attached to the front cover of the linear accelerator that consists of red and green circles printed on A4 paper sheet. A standard mobile phone is placed on the couch to record the video footage during gantry rotation. The video file is subsequently analyzed and used to determine the gantry angle from each video frame using the relative position of the two dots. There were two types of validation tests performed including the static mode with manual gantry angle rotation and dynamic mode with three complex test plans. The accuracy was 0.26° ± 0.04° and 0.46° ± 0.31° (mean ± 1 SD) for the static and dynamic modes, respectively. This method is user friendly, cost effective, easy to setup, has high temporal resolution, and can be combined with existing time-resolved method for QA of MLC and dose rate to form a comprehensive set of procedures for time-resolved QA of VMAT delivery system.

Indexed as

HumansParticle AcceleratorsQuality Assurance, Health CareRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedRotationTime Factorsgantry anglequality assuranceVMAT

Identifiers

PMID28703451
PMCPMC5874941
OpenAlexW2734708782

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.