Evidence map›Paper›PMID 28701857›Full record

ArticleJSLS : Journal of the Society of Laparoendoscopic Surgeons

Laparoscopic Single-Site Inguinal Hernia Repair Using a Self-Fixating Mesh.

Alfredo D Guerron, Hui-Jie Lee, Jin Yoo, Keri Seymour, Ranjan Sudan, Dana Portenier, Chan Park

Abstract read
In one paragraph

Article in JSLS : Journal of the Society of Laparoendoscopic Surgeons. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Robotic single-port surgery: Preliminary experience in general surgery.The international journal of medical robotics + computer assisted surgery : MRCAS · 2022
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alfredo D GuerronDepartment of General Surgery, Duke University Health System, Durham, North Carolina.
Hui-Jie LeeDepartment of Biostatistics and Bioinformatics, Duke University Medical Center, Durham, North Carolina.
Jin YooDepartment of General Surgery, Duke University Health System, Durham, North Carolina.
Keri SeymourDepartment of General Surgery, Duke University Health System, Durham, North Carolina.
Ranjan SudanDepartment of General Surgery, Duke University Health System, Durham, North Carolina.
Dana PortenierDepartment of General Surgery, Duke University Health System, Durham, North Carolina.
Chan ParkDepartment of General Surgery, Duke University Health System, Durham, North Carolina.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesEvery year ∼20 million inguinal hernia repairs are completed worldwide. Increased patient access to medical information and education has elicited interest in minimally invasive surgical techniques that obtain improved surgical outcomes and cosmesis. Because of these factors, there is a growing interest in single-incision surgery. Laparoscopic totally extraperitoneal (TEP) single-incision hernia repair technique has been reported with different meshes used in a tack fixation system. Recently, self-fixating mesh technology has offered the possibility of avoiding tack fixation and potentially avoiding chronic postoperative pain. Self-fixating mesh technology employs monofilament polylactic acid (PLA) creating a microgrip system that provides self-adherence of the mesh to adjacent tissue. This tack-free fixation system provides coverage over the entire myopectineal orifice and surrounding areas where traditional tacks cannot be placed. Self-fixating mesh has also been safely applied in laparoscopic TEP procedures, but this mesh has not been described in single site TEP surgery; possibly because of the potential difficulty with mesh deployment. We sought to determine the technical feasibility of a single-site laparoscopic TEP repair of inguinal hernias and to discuss our techniques and patient short-term outcomes.

methodsReview of a prospectively maintained database of patients who received single-site laparoscopic TEP herniorrhaphy from August 2012 through August 2015. Patient characteristics and demographics and perioperative and postoperative data were analyzed.

resultsThirty-four patients (aged 55.2 ±14.2; 17.6% women) with a mean body mass index of 26.2 ± 3.9 were analyzed. Mean operative time was 99.5 ± 30.5 minutes, 41.2% were left-side repairs, and 50% were bilateral. Estimated blood loss was 18.4 ± 14.1 mL. Recurrent hernias accounted for 14.7% of cases; 32.4% of cases were combination surgeries, most commonly a concurrent umbilical hernia repair. The most common short-term postoperative complication was urinary retention (4 patients). The median length of follow-up was 25 days (IQR 18.75-61.75). Complications occurring at >30 days included hydrocele (2 patients) and stitch abscess (1 patient). Eight (23.5%) patients had complications (surgical or during follow-up). No recurrences or deaths were reported.

conclusionsWith comparable operative times, perioperative outcomes, and safety profile, SS-TEP appears to be a safe and effective surgical approach for the management of inguinal hernias in the short term. Furthermore, SS-TEP with a self-fixating mesh is a feasible approach.

Indexed as

LaparoscopySurgical MeshBlood Loss, SurgicalFemaleHernia, InguinalHumansMaleMiddle AgedOperative TimePostoperative ComplicationsLaparoscopic single-site inguinal hernia repairSelf-fixating mesh

Identifiers

PMID28701857
PMCPMC5506777

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.