Valve-related modes of pump failure in collecting lymphatics: numerical and experimental investigation.

C D Bertram, C Macaskill, M J Davis, J E Moore

Abstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. A multiscale sliding filament model of lymphatic muscle pumping.Biomechanics and modeling in mechanobiology · 2021
    Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

C D BertramSchool of Mathematics and Statistics, University of Sydney, Sydney, NSW, Australia. c.bertram@sydney.edu.au.
C MacaskillSchool of Mathematics and Statistics, University of Sydney, Sydney, NSW, Australia.
M J DavisDepartment of Medical Pharmacology and Physiology, University of Missouri School of Medicine, Columbia, MO, USA.
J E MooreDepartment of Bioengineering, Imperial College, London, UK.

Funding

Lymphatic pacemaking and pumping in lymphedema: function, dysfunction, and rescueR01HL122578 · NHLBI · UNIVERSITY OF MISSOURI-COLUMBIA · PI DAVIS, MICHAEL JOHN · 2015 to 2023
$4.1M
Transport Phenomena in the Lymphatic SystemU01HL123420 · NHLBI · TEXAS A&M UNIVERSITY HEALTH SCIENCE CTR · PI MOORE, JAMES E, ZAWIEJA, DAVID CARL · 2014 to 2018
$2.9M
Lymphatic Fluid Flow Modeling with Active Network ComponentsR01HL094269 · NHLBI · TEXAS ENGINEERING EXPERIMENT STATION · PI KAUNAS, ROLAND RAYMOND · 2009 to 2012
$2.7M
Mechanisms of lymphatic valve and pump dysfunction in lymphedemaR01HL120867 · NHLBI · UNIVERSITY OF MISSOURI-COLUMBIA · PI DAVIS, MICHAEL JOHN · 2014 to 2017
$1.5M
NHLBI NIH HHS R01 HL094269NHLBI NIH HHS R01 HL120867NHLBI NIH HHS R01 HL122578NHLBI NIH HHS U01 HL123420
6 · The paper itself

Abstract

Lymph is transported along collecting lymphatic vessels by intrinsic and extrinsic pumping. The walls have muscle of a type intermediate between blood-vascular smooth muscle and myocardium; a contracting segment between two valves (a lymphangion) constitutes a pump. This intrinsic mechanism is investigated ex vivo in isolated, spontaneously contracting, perfused segments subjected to controlled external pressures. The reaction to varying afterload is probed by slowly ramping up the outlet pressure until pumping fails. Often the failure occurs when the contraction raises intra-lymphangion pressure insufficiently to overcome the outlet pressure, open the outlet valve and cause ejection, but many segments fail by other means, the mechanisms of which are not clear. We here elucidate those mechanisms by resort to a numerical model. Experimental observations are paired with comparable findings from computer simulations, using a lumped-parameter model that incorporates previously measured valve properties, plus new measurements of active contractile and passive elastic properties, and the dependence of contraction frequency on transmural pressure, all taken from isobaric twitch contraction experiments in the same vessel. Surprisingly, the model predicts seven different possible modes of pump failure, each defined by a different sequence of valve events, with their occurrence depending on the parameter values and boundary conditions. Some, but not all, modes were found experimentally. Further model investigation reveals routes by which a vessel exhibiting one mode of failure might under altered circumstances exhibit another.

Indexed as

Heart-Assist DevicesNumerical Analysis, Computer-AssistedAnimalsComputer SimulationHeart ValvesLymphatic SystemModels, BiologicalMuscle ContractionMuscle Fibers, SkeletalPerfusionPressureRatsFluid–structure interactionLymphatic valveLymphatic vesselPump function

Identifiers

PMID28699120
PMCPMC5671905

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.