Evidence map›Paper›PMID 28695479›Full record

ArticleInternational journal of computer assisted radiology and surgery2017

Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.

Juan A Sánchez-Margallo, Francisco M Sánchez-Margallo

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 32 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Bedside Admittance Control of a Dual-Segment Soft Robot for Catheter-Based Interventions.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Juan A Sánchez-MargalloDepartment of Computer Systems and Telematics Engineering, University of Extremadura, Badajoz, Spain.ORCID http://orcid.org/0000-0002-0100-2695
Francisco M Sánchez-MargalloJesús Usón Minimally Invasive Surgical Centre, Ctra. N-521, km 41.8, 10071, Cáceres, Spain. msanchez@ccmijesususon.com.ORCID http://orcid.org/0000-0003-2138-988X
Centro de Cirugía de Mínima Invasión Jesús Usón · ESUniversidad de Extremadura · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks.

methodsSix right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials.

resultsNo statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder.

conclusionsResults have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.

Indexed as

NeedlesSurgeonsSurgical InstrumentsSuture TechniquesAdultClinical CompetenceErgonomicsHumansLaparoscopyRoboticsRobotic Surgical ProceduresTask Performance and AnalysisWristData gloveErgonomicsLaparoscopic surgeryRobotic-driven needle holderSuturing checklist

Identifiers

PMID28695479
OpenAlexW2735083584

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.