Clinical usefulness of MLCs in robotic radiosurgery systems for prostate SBRT.

Masashi Tomida, Takeshi Kamomae, Junji Suzuki, Yoichi Ohashi, Yoshiyuki Itoh, Hiroshi Oguchi, Takahito Okuda

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Masashi TomidaDepartment of Radiology, Toyota Memorial Hospital, Toyota, Japan.
Takeshi KamomaeDepartment of Therapeutic Radiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Junji SuzukiDepartment of Quality Management for Radiotherapy, Toyota Memorial Hospital, Toyota, Japan.
Yoichi OhashiDepartment of Radiology, Toyota Memorial Hospital, Toyota, Japan.
Yoshiyuki ItohDepartment of Therapeutic Radiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Hiroshi OguchiDepartment of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Takahito OkudaDepartment of Radiology, Toyota Memorial Hospital, Toyota, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stereotactic body radiation therapy (SBRT) using recently introduced multileaf collimators (MLC) is preferred over circular collimators in the treatment of localized prostate cancer. The objective of this study was to assess the clinical usefulness of MLCs in prostate SBRT by comparing the effectiveness of treatment plans using fixed collimators, variable collimators, and MLCs and by ensuring delivery quality assurance (DQA) for each. For each patient who underwent conventional radiation therapy for localized prostate cancer, mock SBRT plans were created using a fixed collimator, a variable collimator, and an MLC. The total MUs, treatment times, and dose-volume histograms of the planning target volumes and organs at risk for each treatment plan were compared. For DQA, a phantom with a radiochromic film or an ionization chamber was irradiated in each plan. We performed gamma-index analysis to evaluate the consistency between the measured and calculated doses. The MLC-based plans had an ~27% lower average total MU than the plans involving other collimators. Moreover, the average estimated treatment time for the MLC plan was 31% and 20% shorter than that for the fixed and variable collimator plans respectively. The gamma-index passing rate in the DQA using film measurements was slightly lower for the MLC than for the other collimators. The DQA results acquired using the ionization chamber showed that the discrepancies between the measured and calculated doses were within 3% in all cases. The results reinforce the usefulness of MLCs in robotic radiosurgery for prostrate SBRT treatment planning; most notably, the total MU and treatment time were both reduced compared to the cases using other types of collimators. Moreover, although the DQA results based on film dosimetry yielded a slightly lower gamma-index passing rate for the MLC than for the other collimators, the MLC accuracy was determined to be sufficient for clinical use.

Indexed as

Particle AcceleratorsAgedHumansMaleMiddle AgedProstatic NeoplasmsRadiosurgeryRadiotherapy DosageRobotic Surgical Proceduresmultileaf collimatorpatient-specific quality assuranceprostate cancerrobotic radiosurgery systemstereotactic body radiation therapy

Identifiers

PMID28691256
PMCPMC5875821

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked