ArticleCell biochemistry and biophysics2017
Development of the Implantable Resonator System for Clinical EPR Oximetry.
Article in Cell biochemistry and biophysics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 21 citations in OpenAlex.
- Electron paramagnetic resonance (EPR) meets drug delivery and biomaterials: a magnetic love story.Drug delivery and translational research · 2026Review
- OxyTrack: A Novel Needle Sensor for In Situ Oximetry.Magnetic resonance in medicine · 2026Article
- A Novel Approach to In Vivo EPR Spectroscopy for Repeatable Assessments of Oxygenation Levels in Tumors at Any Depth: Preliminary Feasibility Studies Utilizing a Multisite Oxygen Sensor Inside HDR Brachytherapy Needles.Advances in experimental medicine and biology · 2026Article
- Composite spin probes with adjustable oxygen sensitivity for pulse electron paramagnetic resonance imaging.Magnetic resonance in medicine · 2025Article
- Re-examining What the Results of "a Measurement of Oxygen Level in Tissues" Really Mean.Molecular imaging and biology · 2024Article
- Recognising Potential Ambiguities in Measurements of Oxygen in Tissues.Advances in experimental medicine and biology · 2024Article
- Evaluation of a Refined Implantable Resonator for Deep-Tissue EPR Oximetry in the Clinic.Applied magnetic resonance · 2021Article
- First-In-Human Study in Cancer Patients Establishing the Feasibility of Oxygen Measurements in Tumors Using Electron Paramagnetic Resonance With the OxyChip.Frontiers in oncology · 2021Article
- Oxygen-Sensing Paramagnetic Probes for Clinical Oximetry.Advances in experimental medicine and biology · 2021Article
- Wireless implantable coil with parametric amplification for in vivo electron paramagnetic resonance oximetric applications.Magnetic resonance in medicine · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 1 institution in 1 country.
Funding
Abstract
Hypoxic tumors are more resistant to radiotherapy and chemotherapy, which decreases the efficacy of these common forms of treatment. We have been developing implantable paramagnetic particulates to measure oxygen in vivo using electron paramagnetic resonance. Once implanted, oxygen can be measured repeatedly and non-invasively in superficial tissues (<3 cm deep), using an electron paramagnetic resonance spectrometer and an external surface-loop resonator. To significantly extend the clinical applications of electron paramagnetic resonance oximetry, we developed an implantable resonator system to obtain measurements at deeper sites. This system has been used to successfully obtain oxygen measurements in animal studies for several years. We report here on recent developments needed to meet the regulatory requirements to make this technology available for clinical use. radio frequency heating is discussed and magnetic resonance compatibility testing of the device has been carried out by a Good Laboratory Practice-certified laboratory. The geometry of the implantable resonator has been modified to meet our focused goal of verifying safety and efficacy for the proposed use of intracranial measurements and also for future use in tissue sites other than the brain. We have encapsulated the device within a smooth cylindrical-shaped silicone elastomer to prevent tissues from adhering to the device and to limit perturbation of tissue during implantation and removal. We have modified the configuration for simultaneously measuring oxygen at multiple sites by developing a linear array of oxygen sensing probes, which each provide independent measurements. If positive results are obtained in additional studies which evaluate biocompatibility and chemical characterization, we believe the implantable resonator will be at a suitable stage for initial testing in human subjects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.