Evidence map›Paper›PMID 28684332›Full record

ReviewNeuroImage2018

Spinal cord MRI at 7T.

Robert L Barry, S Johanna Vannesjo, Samantha By, John C Gore, Seth A Smith

Abstract readReview
In one paragraph

Review in NeuroImage, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 48 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Spinal cord imaging in multiple sclerosis: A vital component we can no longer overlook.Multiple sclerosis (Houndmills, Basingstoke, England) · 2026
    Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Review
  13. Article
  14. Review
  15. Article
  16. Review
  17. Spinal Cord fMRI: A New Window into the Central Nervous System.The Neuroscientist : a review journal bringing neurobiology, neurology and psychiatry · 2023
    Review
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Robert L BarryAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA. Electronic address: Robert.Barry@mgh.Harvard.edu.
S Johanna VannesjoOxford Centre for Functional MRI of the Brain (FMRIB), Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
Samantha ByVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
John C GoreVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
Seth A SmithVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.

Funding

Vanderbilt Institute for Clinical and Translational Research (VICTR) -Identifying correlates of functional immunity in SARS-CoV-2 convalescent plasmaUL1TR002243 · NCATS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI Paul A. Harris, Wesley H Self · 2017 to 2026
$130.7M
VANDERBILT UNIVERSITY CTSA FOR PEDIATRIC RESEARCHUL1RR024975 · NCRR · VANDERBILT UNIVERSITY · PI BERNARD, GORDON RAPHAEL · 2007 to 2011
$45.7M
The Vanderbilt Institute for Clinical and Translational Research (VICTR)UL1TR000445 · NCATS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI BERNARD, GORDON RAPHAEL · 2012 to 2016
$41.4M
Research Project: Sensory and Multisensory Contributions to AutismU54HD083211 · NICHD · VANDERBILT UNIVERSITY MEDICAL CENTER · PI DYKENS, ELISABETH MAY · 2015 to 2019
$7.1M
Resting State Connectivity in Primate Spinal CordR01NS092961 · NINDS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI CHEN, LI MIN, GORE, JOHN C · 2016 to 2025
$5.3M
7 Tesla Human Magnetic Resonance Imaging and Spectroscopy SystemS10RR023047 · NCRR · VANDERBILT UNIVERSITY · PI GORE, JOHN C · 2007 to 2007
$2.0M
Resting State FMRI as a Biomarker of Functional Integrity of Spinal CordR01NS104149 · NINDS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI GORE, JOHN C · 2017 to 2020
$1.5M
Functional Imaging and resting state connectivity in human spinal cord at 7 TeslaR00EB016689 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI BARRY, ROBERT L · 2016 to 2018
$747k
Investigation of Resting State Functional Connectivity in the Human Spinal CordR21NS081437 · NINDS · VANDERBILT UNIVERSITY · PI GORE, JOHN C · 2013 to 2014
$427k
Functional Imaging and Resting State Connectivity in Human Spinal Cord at 7 TeslaK99EB016689 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI BARRY, ROBERT L · 2014 to 2015
$178k
NCATS NIH HHS UL1 TR000445NCATS NIH HHS UL1 TR002243NCRR NIH HHS S10 RR023047NCRR NIH HHS UL1 RR024975NIBIB NIH HHS K99 EB016689NIBIB NIH HHS R00 EB016689NICHD NIH HHS U54 HD083211NINDS NIH HHS R01 NS092961NINDS NIH HHS R01 NS104149NINDS NIH HHS R21 NS081437
6 · The paper itself

Abstract

Magnetic resonance imaging (MRI) of the human spinal cord at 7T has been demonstrated by a handful of research sites worldwide, and the spinal cord remains one of the areas in which higher fields and resolution could have high impact. The small diameter of the cord (∼1 cm) necessitates high spatial resolution to minimize partial volume effects between gray and white matter, and so MRI of the cord can greatly benefit from increased signal-to-noise ratio and contrasts at ultra-high field (UHF). Herein we review the current state of UHF spinal cord imaging. Technical challenges to successful UHF spinal cord MRI include radiofrequency (B

Indexed as

HumansMagnetic Resonance ImagingNeuroimagingSpinal Cord

Identifiers

PMID28684332
PMCPMC5894871

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.