Evidence map›Paper›PMID 28683124›Full record

ArticlePloS one2017

Hybrid spectral CT reconstruction.

Darin P Clark, Cristian T Badea

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 55 citations in OpenAlex.

  1. Article
  2. Article
  3. Image-Guided Cardiac Regeneration via a 3D Bioprinted Vascular Patch with Built-in CT Visibility.Chemical engineering journal (Lausanne, Switzerland : 1996) · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Advances in micro-CT imaging of small animals.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2021
    Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Darin P ClarkCenter for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, NC, United States of America.
Cristian T BadeaCenter for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, NC, United States of America.ORCID http://orcid.org/0000-0002-1850-2522
Duke Medical Center · US

Funding

INTEGRATED CENTER FOR IN VIVO MICROSCOPYP41EB015897 · NIBIB · DUKE UNIVERSITY · PI JOHNSON, GEORGE ALLAN · 2012 to 2017
$7.4M
Development of a New Generation Micro-CT imaging for Functional and Molecular Imaging of CancerR01CA196667 · NCI · DUKE UNIVERSITY · PI BADEA, CRISTIAN T · 2015 to 2019
$2.3M
NCI NIH HHS R01 CA196667NIBIB NIH HHS P41 EB015897
6 · The paper itself

Abstract

Current photon counting x-ray detector (PCD) technology faces limitations associated with spectral fidelity and photon starvation. One strategy for addressing these limitations is to supplement PCD data with high-resolution, low-noise data acquired with an energy-integrating detector (EID). In this work, we propose an iterative, hybrid reconstruction technique which combines the spectral properties of PCD data with the resolution and signal-to-noise characteristics of EID data. Our hybrid reconstruction technique is based on an algebraic model of data fidelity which substitutes the EID data into the data fidelity term associated with the PCD reconstruction, resulting in a joint reconstruction problem. Within the split Bregman framework, these data fidelity constraints are minimized subject to additional constraints on spectral rank and on joint intensity-gradient sparsity measured between the reconstructions of the EID and PCD data. Following a derivation of the proposed technique, we apply it to the reconstruction of a digital phantom which contains realistic concentrations of iodine, barium, and calcium encountered in small-animal micro-CT. The results of this experiment suggest reliable separation and detection of iodine at concentrations ≥ 5 mg/ml and barium at concentrations ≥ 10 mg/ml in 2-mm features for EID and PCD data reconstructed with inherent spatial resolutions of 176 μm and 254 μm, respectively (point spread function, FWHM). Furthermore, hybrid reconstruction is demonstrated to enhance spatial resolution within material decomposition results and to improve low-contrast detectability by as much as 2.6 times relative to reconstruction with PCD data only. The parameters of the simulation experiment are based on an in vivo micro-CT experiment conducted in a mouse model of soft-tissue sarcoma. Material decomposition results produced from this in vivo data demonstrate the feasibility of distinguishing two K-edge contrast agents with a spectral separation on the order of the energy resolution of the PCD hardware.

Indexed as

PhotonsAnimalsBariumCalciumContrast MediaIodineMicePhantoms, ImagingRadiographic Image Interpretation, Computer-AssistedSarcomaSoft Tissue NeoplasmsTomography, X-Ray ComputedBariumCalciumContrast MediaIodine

Identifiers

PMID28683124
PMCPMC5500339
OpenAlexW2725502121

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.