Evidence map›Paper›PMID 28681283›Full record

ArticleUpdates in surgery2017

The visualization of gastro-esophageal junction vascular supply during a laparoscopic sleeve gastrectomy. Role of a new device.

Mario Musella, Marco Milone, Paolo Bianco, Francesco Milone

Abstract read
PubMed Publisher
In one paragraph

Article in Updates in surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Mario MusellaAdvanced Biomedical Sciences Department, AOU "Federico II", "Federico II" University, Via S. Pansini 5 Building 12, 80131, Naples, Italy. mario.musella@unina.it.ORCID http://orcid.org/0000-0002-7669-5115
Marco MiloneAdvanced Biomedical Sciences Department, AOU "Federico II", "Federico II" University, Via S. Pansini 5 Building 12, 80131, Naples, Italy.
Paolo BiancoAdvanced Biomedical Sciences Department, AOU "Federico II", "Federico II" University, Via S. Pansini 5 Building 12, 80131, Naples, Italy.
Francesco MiloneAdvanced Biomedical Sciences Department, AOU "Federico II", "Federico II" University, Via S. Pansini 5 Building 12, 80131, Naples, Italy.
Federico II University Hospital · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Leaks arising at the level of gastro-esophageal junction remain a major complication in patients who undergo a laparoscopic sleeve gastrectomy. Besides technical pitfalls, these fistulas are mainly attributable to tissue ischemia following the preparation of the gastric sleeve, explained by the irregular vascularization often present in the area of the gastro-esophageal junction. This video presentation shows how, the utilization of a new model of bougie can be of help in preventing a leak, allowing a better visualization of the particular vascular anatomy present at the level of the gastro-esophageal junction area. Currently, 25/334 (18 F-7 M) (7.4%) patients, who underwent a laparoscopic sleeve gastrectomy at our institution, were operated on using this new model of bougie. No leaks have been so far reported.

Indexed as

AdultEsophagogastric JunctionFemaleGastrectomyHumansLaparoscopyMaleMiddle AgedRadiographyYoung AdultDouble lumen bougieGastroesophageal junctionPostoperative leaksSleeve gastrectomyVascular supplyVisualization

Identifiers

PMID28681283
OpenAlexW2733894814

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.