Evidence map›Paper›PMID 28680843›Full record

ArticleImaging science in dentistry2017

Application of a newly developed software program for image quality assessment in cone-beam computed tomography.

Marcus Vinicius Linhares de Oliveira, António Carvalho Santos, Graciano Paulo, Paulo Sergio Flores Campos, Joana Santos

Abstract read
In one paragraph

Article in Imaging science in dentistry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Marcus Vinicius Linhares de OliveiraDepartment of Health Technology and Biology, Federal Institute of Bahia, Salvador, BA, Brazil.
António Carvalho SantosDepartment of Complementary Sciences, Coimbra Health School, Polytechnic Institute of Coimbra, Portugal.
Graciano PauloDepartment of Medical Imaging and Radiotherapy, Coimbra Health School, Polytechnic Institute of Coimbra, Portugal.
Paulo Sergio Flores CamposDepartment of Interactive Processes of Organs and Systems, Institute of Health Sciences, Federal University of Bahia, Salvador, BA, Brazil.
Joana SantosDepartment of Medical Imaging and Radiotherapy, Coimbra Health School, Polytechnic Institute of Coimbra, Portugal.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. MATERIALS AND

methodsA polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution.

resultsThe image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence.

conclusionThis software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

Indexed as

Cone-Beam Computed TomographyImage QualityQuality AssuranceQuality Control

Identifiers

PMID28680843
PMCPMC5489672

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.