ArticleEuropean radiology2018
Development of a reliable simulation-based test for diagnostic abdominal ultrasound with a pass/fail standard usable for mastery learning.
Article in European radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Simulator training improves ultrasound scanning performance on patients: a randomized controlled trial.European radiology · 2019Trial
- Setting proficiency standards for simulation-based mastery learning of short antegrade femoral nail osteosynthesis: a multicenter study.Acta orthopaedica · 2024Article
- Can virtual-reality simulation ensure transthoracic echocardiography skills before trainees examine patients?International journal of medical education · 2022Article
- Development of an expert consensus checklist for emergency ultrasound.AEM education and training · 2022Article
- Use of an Online Ultrasound Simulator to Teach Basic Psychomotor Skills to Medical Students During the Initial COVID-19 Lockdown: Quality Control Study.JMIR medical education · 2021Article
- The Use of Diaphragm Ultrasonography in Pulmonary Physiotherapy of COPD Patients: A Literature Review.Journal of clinical medicine · 2020Review
- Simulation-Based Virtual-Reality Patient-Specific Rehearsal Prior to Endovascular Procedures: A Systematic Review.Diagnostics (Basel, Switzerland) · 2020Review
- Four Virtual-Reality Simulators for Diagnostic Abdominal Ultrasound Training in Radiology.Diagnostics (Basel, Switzerland) · 2019Article
- Lung ultrasound training: a systematic review of published literature in clinical lung ultrasound training.Critical ultrasound journal · 2018Review
- Determining procedures for simulation-based training in radiology: a nationwide needs assessment.European radiology · 2018Article
- The ultrasound use of simulators, current view, and perspectives: Requirements and technical aspects (WFUMB state of the art paper).Endoscopic ultrasoundReview
- The use of simulation in medical ultrasound: Current perspectives on applications and practical implementation (WFUMB state-of-the-art paper).Endoscopic ultrasoundArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThis study aimed to develop a test with validity evidence for abdominal diagnostic ultrasound with a pass/fail-standard to facilitate mastery learning.
methodThe simulator had 150 real-life patient abdominal scans of which 15 cases with 44 findings were selected, representing level 1 from The European Federation of Societies for Ultrasound in Medicine and Biology. Four groups of experience levels were constructed: Novices (medical students), trainees (first-year radiology residents), intermediates (third- to fourth-year radiology residents) and advanced (physicians with ultrasound fellowship). Participants were tested in a standardized setup and scored by two blinded reviewers prior to an item analysis.
resultsThe item analysis excluded 14 diagnoses. Both internal consistency (Cronbach's alpha 0.96) and inter-rater reliability (0.99) were good and there were statistically significant differences (p < 0.001) between all four groups, except the intermediate and advanced groups (p = 1.0). There was a statistically significant correlation between experience and test scores (Pearson's r = 0.82, p < 0.001). The pass/fail-standard failed all novices (no false positives) and passed all advanced (no false negatives). All intermediate participants and six out of 14 trainees passed.
conclusionWe developed a test for diagnostic abdominal ultrasound with solid validity evidence and a pass/fail-standard without any false-positive or false-negative scores. KEY POINTS: • Ultrasound training can benefit from competency-based education based on reliable tests. • This simulation-based test can differentiate between competency levels of ultrasound examiners. • This test is suitable for competency-based education, e.g. mastery learning. • We provide a pass/fail standard without false-negative or false-positive scores.
Indexed as
Identifiers
28677051What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.