Evidence map›Paper›PMID 28674964›Full record

ArticleEuropean radiology2017

Gadobutrol versus gadofosveset-trisodium in MR venography of the lower extremities.

Carsten W K P Arnoldussen, Yeelai Lam, Nobutake Ito, Bjorn Winkens, M Eline Kooi, Cees H A Wittens, Joachim E Wildberger

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 4 countries.

Carsten W K P ArnoldussenDepartment of Radiology, Maastricht University Medical Center, P.O. Box 5800, P.Debyelaan 25, 6202 AZ, Maastricht, The Netherlands. Carsten.arnoldussen@mumc.nl.
Yeelai LamDepartment of Vascular Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
Nobutake ItoDepartment of Diagnostic Radiology, National Hospital Organization Tokyo Medical Center, Tokyo, Japan.
Bjorn WinkensDepartment of Methodology and Statistics, Maastricht University, Maastricht, The Netherlands.
M Eline KooiDepartment of Radiology, Maastricht University Medical Center, P.O. Box 5800, P.Debyelaan 25, 6202 AZ, Maastricht, The Netherlands.
Cees H A WittensDepartment of Vascular Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
Joachim E WildbergerDepartment of Radiology, Maastricht University Medical Center, P.O. Box 5800, P.Debyelaan 25, 6202 AZ, Maastricht, The Netherlands.
Maastricht University · NLUniversity Medical Center · USRWTH Aachen University · DETokyo Medical Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesMR venography (MRV) protocols have used bloodpool contrast agents and long scan sequences to identify patients suitable for treatment and preoperatively. However, variable availability of bloodpool contrast agents, high costs and a need to shorten acquisition times for routine MR protocols hamper everyday practice. MATERIALS: 20 patients (11 men; mean age 54 ± 11.8 years; body mass index 23.6 ± 2.5) were enrolled in this prospective study. An intra-individual comparison of image quality, interpretation and findings for two different contrast agents (regular gadolinium contrast agent gadobutrol vs. bloodpool contrast agent gadofosveset-trisodium) and two different scan protocols (long acquisition time protocol using a high-resolution fast field echo (FFE) sequence vs. short acquisition time protocol using an ultra-fast gradient echo (GE) sequence) were performed.

resultsImage quality (average of 4.94 vs. 4.92 on a five-point scale), interpretation and contrast-to-noise ratio (44 vs. 45) were equal for both contrast agents. Image findings showed no statistical significant differences between the MR protocols or contrast agents (overall p = 0.328).

conclusionsFor high-resolution MRV, it is possible to replace gadofosveset-trisodium with gadobutrol. Furthermore, an ultra-fast GE sequence for MRV might considerably shorten acquisition time, without loss of image quality or diagnostic yield. KEY POINTS: • High-quality MRV can be performed with a regular gadolinium-based contrast agent. • Ultra-fast GRE vs. HR-FFE MRV: equally suitable for evaluation of venous obstruction. • Regular gadolinium-based contrast agent can supersede a bloodpool contrast agent for MRV. • Equal confidence for gadobutrol vs gadofosveset-trisodium in MRV. • MRV accessible for routine daily practice.

Indexed as

Contrast MediaGadoliniumOrganometallic CompoundsAdultAgedFemaleHumansLower ExtremityMagnetic Resonance ImagingMaleMiddle AgedPhlebographyProspective StudiesVenous ThrombosisYoung AdultContrast MediagadobutrolGadoliniumOrganometallic CompoundsChronic venous diseaseChronic venous obstructionMRIMR venographyVenous

Identifiers

PMID28674964
PMCPMC5674132
OpenAlexW2731575633

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.