Evidence map›Paper›PMID 28669116›Full record

Trial reportSleep & breathing = Schlaf & Atmung2017

Validation of ApneaLink™ Plus for the diagnosis of sleep apnea.

Jae Hoon Cho, Hyun Jun Kim

Abstract readClinical TrialValidation Study
PubMed Publisher
In one paragraph

Trial report in Sleep & breathing = Schlaf & Atmung, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Performance comparison of peripheral arterial tonometry-based testing and polysomnography to diagnose obstructive sleep apnea in military personnel.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2022
    Article
  19. Article
  20. Moving beyond the AHI.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Jae Hoon ChoDepartment of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Konkuk University, Seoul, South Korea.
Hyun Jun KimDepartment of Otolaryngology, School of Medicine, Ajou University, Woncheon-dong, Yeongtong-gu, Suwon, Gyeonggi-do, 443-721, South Korea. entkhj@ajou.ac.kr.

Funding

the Korean Health Technology HC15C3415
6 · The paper itself

Abstract

purposeThe aim of this study is to evaluate the validation of ApneaLink™ Plus (ALP) based on a large number of subjects in a prospective design.

methodWe recommended enrolling of 200 consecutive patients who had been referred because of habitual snoring or witnessed apnea during sleep. If consent was obtained, patients underwent standard polysomnography (PSG) and ALP evaluation simultaneously at the hospital (ALP

resultAmong the 200 patients who were recommended for enrollment, 149 completed the study. Sensitivity was good for all three scoring systems, while specificity was poor for the Auto scoring system. The area under curve was highest for the manual scoring system and lowest for the auto scoring system, and increased as the apnea-hypopnea index (AHI) cutoff value increased from 5 to 30. Regarding agreement with PSG, the manual scoring system was most superior, followed by the Auto AASM, and Auto scoring systems. The degree of agreement between PSG and ALP was affected by sleep efficiency and the arousal index. Moderate agreement between PSG and ALP based on central apnea index was observed.

conclusionALP is an accurate and reliable device for the diagnosis of OSA. Manual scoring is recommended; however, Auto AASM is also acceptable. ALP detects central sleep apnea to a certain degree. Both sleep efficiency and the arousal index affect the results of ALP.

Indexed as

AdultArousalFemaleHumansMaleMiddle AgedPolysomnographyProspective StudiesSleepSleep Apnea, ObstructiveObstructive sleep apneaPortable sleep monitoringValidation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked