Evidence map›Paper›PMID 28666026›Full record

ArticlePloS one2017

Assessing agreement between preclinical magnetic resonance imaging and histology: An evaluation of their image qualities and quantitative results.

Cindy Elschner, Paula Korn, Maria Hauptstock, Matthias C Schulz, Ursula Range, Diana Jünger, Ulrich Scheler

Abstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Cindy ElschnerLeibniz Institute of Polymer Research Dresden, Dresden, Germany.
Paula KornDepartment of Oral and Maxillofacial Surgery, Faculty of Medicine »Carl Gustav Carus«, Technische Universität Dresden, Dresden, Germany.
Maria HauptstockDepartment of Oral and Maxillofacial Surgery, Faculty of Medicine »Carl Gustav Carus«, Technische Universität Dresden, Dresden, Germany.
Matthias C SchulzDepartment of Oral and Maxillofacial Surgery, Faculty of Medicine »Carl Gustav Carus«, Technische Universität Dresden, Dresden, Germany.
Ursula RangeInstitute for Medical Informatics and Biometry, Faculty of Medicine »Carl Gustav Carus«, Technische Universität Dresden, Dresden, Germany.
Diana JüngerDepartment of Oral and Maxillofacial Surgery, Faculty of Medicine »Carl Gustav Carus«, Technische Universität Dresden, Dresden, Germany.
Ulrich SchelerLeibniz Institute of Polymer Research Dresden, Dresden, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One consequence of demographic change is the increasing demand for biocompatible materials for use in implants and prostheses. This is accompanied by a growing number of experimental animals because the interactions between new biomaterials and its host tissue have to be investigated. To evaluate novel materials and engineered tissues the use of non-destructive imaging modalities have been identified as a strategic priority. This provides the opportunity for studying interactions repeatedly with individual animals, along with the advantages of reduced biological variability and decreased number of laboratory animals. However, histological techniques are still the golden standard in preclinical biomaterial research. The present article demonstrates a detailed method comparison between histology and magnetic resonance imaging. This includes the presentation of their image qualities as well as the detailed statistical analysis for assessing agreement between quantitative measures. Exemplarily, the bony ingrowth of tissue engineered bone substitutes for treatment of a cleft-like maxillary bone defect has been evaluated. By using a graphical concordance analysis the mean difference between MRI results and histomorphometrical measures has been examined. The analysis revealed a slightly but significant bias in the case of the bone volume [Formula: see text] and a clearly significant deviation for the remaining defect width [Formula: see text] But the study although showed a considerable effect of the analyzed section position to the quantitative result. It could be proven, that the bias of the data sets was less originated due to the imaging modalities, but mainly on the evaluation of different slice positions. The article demonstrated that method comparisons not always need the use of an independent animal study, additionally.

Indexed as

AnimalsBiocompatible MaterialsBone SubstitutesCattleMagnetic Resonance ImagingMaleRatsRats, Inbred LewTissue EngineeringBiocompatible MaterialsBone Substitutes

Identifiers

PMID28666026
PMCPMC5493293

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.