Design of a Compact Actuation and Control System for Flexible Medical Robots.

Tania K Morimoto, Elliot Wright Hawkes, Allison M Okamura

Abstract read
In one paragraph

Article in IEEE robotics and automation letters, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Mechatronic Design of a Two-Arm Concentric Tube Robot System for Rigid Neuroendoscopy.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2020
    Article
  2. Wire-driven flexible manipulator with constrained spherical joints for minimally invasive surgery.International journal of computer assisted radiology and surgery · 2019
    Article
  3. Towards Patient-Specific 3D-Printed Robotic Systems for Surgical Interventions.IEEE transactions on medical robotics and bionics · 2019
    Article
  4. Article
  5. Toward the Design of Personalized Continuum Surgical Robots.Annals of biomedical engineering · 2018
    Article
  6. Design of patient-specific concentric tube robots using path planning from 3-D ultrasound.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tania K MorimotoDepartment of Mechanical Engineering, Stanford University, Stanford, CA 94035 USA.
Elliot Wright HawkesDepartment of Mechanical Engineering, Stanford University, Stanford, CA 94035 USA and also with the Department of Mechanical Engineering, University of California, Santa Barbara, CA 93106 USA.
Allison M OkamuraDepartment of Mechanical Engineering, Stanford University, Stanford, CA 94035 USA.

Funding

Ultrasound-Guided Robotic Needle Steering for Ablation of Liver CancerR01EB018849 · NIBIB · STANFORD UNIVERSITY · PI OKAMURA, ALLISON MARIKO · 2014 to 2017
$1.4M
NIBIB NIH HHS R01 EB018849
6 · The paper itself

Abstract

Flexible medical robots can improve surgical procedures by decreasing invasiveness and increasing accessibility within the body. Using preoperative images, these robots can be designed to optimize a procedure for a particular patient. To minimize invasiveness and maximize biocompatibility, the actuation units of flexible medical robots should be placed fully outside the patient's body. In this letter, we present a novel, compact, lightweight, modular actuation, and control system for driving a class of these flexible robots, known as concentric tube robots. A key feature of the design is the use of three-dimensional printed waffle gears to enable compact control of two degrees of freedom within each module. We measure the precision and accuracy of a single actuation module and demonstrate the ability of an integrated set of three actuation modules to control six degrees of freedom. The integrated system drives a three-tube concentric tube robot to reach a final tip position that is on average less than 2 mm from a given target. In addition, we show a handheld manifestation of the device and present its potential applications.

Indexed as

Mechanism designmedical robots and systemssurgical robotics: steerable catheters/needles

Identifiers

PMID28664187
PMCPMC5484156

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.