ArticlePloS one2017
The relationship between minute ventilation and end tidal CO2 in intubated and spontaneously breathing patients undergoing procedural sedation.
Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 1 synthesis or guideline pooled it, 33 citations in OpenAlex.
- The effects of oral contraceptives on resting autonomic function and the autonomic response to physiological stressors: a systematic review.Clinical autonomic research : official journal of the Clinical Autonomic Research Society · 2023Pooled it
- Phase II study comparing nasal pressure monitoring with capnography during invasive endoscopic procedures: a single-center, single-arm trial.Scientific reports · 2023Trial
- An exploratory feasibility study of a novel portable mainstream capnograph in a prehospital environment.International journal of emergency medicine · 2026Article
- Relationships between capnogram parameters by mainstream and sidestream techniques at different breathing frequencies.Scientific reports · 2024Article
- A non-invasive continuous and real-time volumetric monitoring in spontaneous breathing subjects based on bioimpedance-ExSpiron®Xi: a validation study in healthy volunteers.Journal of clinical monitoring and computing · 2024Article
- Does a change in end-tidal carbon dioxide level predict high altitude mountain sickness?Heliyon · 2023Article
- Near-Infrared Spectroscopy Usefulness in Validation of Hyperventilation Test.Medicina (Kaunas, Lithuania) · 2022Article
- Human Exhalation COACS omega · 2022Article
- A Successful Outcome of Veno-Venous Extracorporeal Membrane Oxygenation in Obese Patients with Respiratory Failure in the Course of COVID-19: A Report of Two Cases.International journal of environmental research and public health · 2022Article
- Article
- Comparison of Respiratory Effects between Dexmedetomidine and Propofol Sedation for Ultrasound-Guided Radiofrequency Ablation of Hepatic Neoplasm: A Randomized Controlled Trial.Journal of clinical medicine · 2021Article
- Methods for Estimating Energy Expenditure in Critically Ill Adults.AACN advanced critical care · 2020Article
- Evaluation of end-tidal carbon dioxide gradient as a predictor of volume responsiveness in spontaneously breathing healthy adults.Intensive care medicine experimental · 2018Article
- Article
- An innovative way of monitoring end-tidal carbon dioxide during endoscopic retrograde cholangiopancreatography.Saudi journal of anaesthesiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMonitoring respiratory status using end tidal CO2 (EtCO2), which reliably reflects arterial PaCO2 in intubated patients under general anesthesia, has often proven both inaccurate and inadequate when monitoring non-intubated and spontaneously breathing patients. This is particularly important in patients undergoing procedural sedation (e.g., endoscopy, colonoscopy). This can be undertaken in the operating theater, but is also often delivered outside the operating room by non-anesthesia providers. In this study we evaluated the ability for conventional EtCO2 monitoring to reflect changes in ventilation in non-intubated surgical patients undergoing monitored anesthesia care and compared and contrasted these findings to both intubated patients under general anesthesia and spontaneously breathing volunteers.
methodsMinute Ventilation (MV), tidal volume (TV), and respiratory rate (RR) were continuously collected from an impedance-based Respiratory Volume Monitor (RVM) simultaneously with capnography data in 160 patients from three patient groups: non-intubated surgical patients managed using spinal anesthesia and Procedural Sedation (n = 58); intubated surgical patients under General Anesthesia (n = 54); and spontaneously breathing Awake Volunteers (n = 48). EtCO2 instrument sensitivity was calculated for each patient as the slope of a Deming regression between corresponding measurements of EtCO2 and MV and expressed as angle from the x-axis (θ). All data are presented as mean ± SD unless otherwise indicated.
resultsWhile, as expected, EtCO2 and MV measurements were negatively correlated in most patients, we found gross systematic differences across the three cohorts. In the General Anesthesia patients, small changes in MV resulted in large changes in EtCO2 (high sensitivity, θ = -83.6 ± 9.9°). In contrast, in the Awake Volunteers patients, large changes in MV resulted in insignificant changes in EtCO2 (low sensitivity, θ = -24.7 ± 19.7°, p < 0.0001 vs General Anesthesia). In the Procedural Sedation patients, EtCO2 sensitivity showed a bimodal distribution, with an approximately even split between patients showing high EtCO2 instrument sensitivity, similar to those under General Anesthesia, and patients with low EtCO2 instrument sensitivity, similar to the Awake Volunteers.
conclusionsWhen monitoring non-intubated patients undergoing procedural sedation, EtCO2 often provides inadequate instrument sensitivity when detecting changes in ventilation. This suggests that augmenting standard patient care with EtCO2 monitoring is a less than optimal solution for detecting changes in respiratory status in non-intubated patients. Instead, adding direct monitoring of MV with an RVM may be preferable for continuous assessment of adequacy of ventilation in non-intubated patients.
Indexed as