Evidence map›Paper›PMID 28658104›Full record

ArticleMedicine2017

Thrombotic complications and tip position of transjugular chronic dialysis catheter scheduled into superior vena cava: Findings on HR-MRCP and HR-T2WI.

Whenzheng Li, Fang Li, He Wang, Xueying Long, Obin Ghimire, Yigang Pei, Xiangcheng Xiao, Jianping Ning

Open access · goldAbstract read
In one paragraph

Article in Medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Whenzheng LiDepartment of Radiology, Xiangya Hospital, Central South University, Changsha Philips Healthcare, Buiding, Shanghai Department of Nephrology, Xiangya Hospital, Central South University, Changsha, China.
Fang Li
He Wang
Xueying Long
Obin Ghimire
Yigang Pei
Xiangcheng Xiao
Jianping Ning
Xiangya Hospital Central South University · CNCentral South University · CNPhilips (Finland) · FI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCatheter-related thrombotic complications(TCs) can occur during the long term use of a chronic dialysis catheter (CDC), including fibrin sheath (FS), mural thrombosis (MT), venous thrombosis (VT), and intraluminal clots (IC), which has not been reported with MRI. The aim of our study was to evaluate the determination of catheter tip position (TP) and resolution of TCs in patients with transjugular CDC scheduled into the superior vena cava using high resolution magnetic resonance cholangiopancreatography (HR-MRCP) and T2-weighted imaging (HR-T2WI).

methodsThe study protocol was approved by the local Research Ethics Committee. Informed consent was obtained from all patients. In total, 41 consecutively enrolled transjugular CDC patients with suspected catheter dysfunction were scanned with HRMRCP and HR-T2WI. The distance from the top to the tip of the catheter and the presence and nature of catheter TCs were assessed by 2 experienced radiologists. Chest x-ray was taken within 1 to 2 days and CDC was withdrawn within 3 to 10 days from those patients with TCs identified by HR-MRI.

resultsA total of 38 subjects successfully underwent HR-MRI, including 13 normal and 25 with TCs (fibrin sheath [FS]: n = 21, mural thrombosis [MT]: n = 7, venous thrombosis [VT]: n = 3, intraluminal clots [IC]: n = 4). There was no significant difference between HR-MRCP and chest x-ray in catheter TP determination (P = .124). Normal catheter appeared as "double eyes" on HR-T2WI and "double tracks" on HR-MRCP. TCs appeared as follows: FS displayed as a "thin ring" (<1mm) around the catheter, MT as patchy hyperintensity and VT as a "thick ring" (>5mm) on HR-T2WI. Unilateral IC appeared as a "single eye" on HR-T2WI and a "single track" on HR-MRCP (n = 3). Bilateral IC appeared as neither "eye" nor "track" (n = 1). Catheter withdrawal confirmed FS (n = 16), MT (n = 6), VT (n = 1), and IC (n = 4).

conclusionHR-MRCP and HR-T2WI are promising methods for visualizing TP and TCs in CDC patients, and are helpful in adjusting the treatment plan and avoiding the risk of pulmonary embolism.

Indexed as

Magnetic Resonance ImagingCatheterization, Central VenousCholangiopancreatography, Magnetic ResonanceFemaleHumansKidney Failure, ChronicMaleMiddle AgedProspective StudiesRadiography, ThoracicRenal DialysisThrombosisVena Cava, Superior

Identifiers

PMID28658104
PMCPMC5500026
OpenAlexW2729863229

What OpenQuestion holds

Textmetadata
LicenceCC BY-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.