ArticleMagnetic resonance in medicine2018
Cardiac quantitative susceptibility mapping (QSM) for heart chamber oxygenation.
Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 32 citations in OpenAlex.
- Leveraging Self-Supervised Learning for Non-Invasive Intra-Cardiac Magnetic Resonance Oximetry Assessment.medRxiv : the preprint server for health sciences · 2026Article
- Quantitative Susceptibility Mapping in Skull Base Chordoma: In Silico Analysis and In Vivo Application Towards Indirect Hypoxia Assessment.Magnetic resonance in medicine · 2026Article
- Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation-Initial validation in relation to invasive blood sampling.Magnetic resonance in medicine · 2025Article
- 5D image reconstruction exploiting space-motion-echo sparsity for accelerated free-breathing quantitative liver MRI.Medical image analysis · 2025Article
- Water/fat separate reconstruction for body quantitative susceptibility mapping in MRI.Radiological physics and technology · 2025Article
- Application of multi-echo susceptibility weighted imaging in the evaluation of brain capillary telangiectasias.Frontiers in neurology · 2025Article
- Accurate Intramyocardial Hemorrhage Assessment with Fast, Free-running, Cardiac Quantitative Susceptibility Mapping.Radiology. Cardiothoracic imaging · 2024Article
- Reliable Off-Resonance Correction in High-Field Cardiac MRI Using Autonomous Cardiac BBioengineering (Basel, Switzerland) · 2024Article
- Trajectory correction enables free-running chemical shift encoded imaging for accurate cardiac proton-density fat fraction quantification at 3T.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024 · on this mapArticle
- Toward a realistic in silico abdominal phantom for QSM.Magnetic resonance in medicine · 2023Article
- QSM Throughout the Body.Journal of magnetic resonance imaging : JMRI · 2023Review
- LARO: Learned acquisition and reconstruction optimization to accelerate quantitative susceptibility mapping.NeuroImage · 2023Article
- Quantitative susceptibility mapping (QSM) of the cardiovascular system: challenges and perspectives.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2022Review
- Can myocardial susceptibility quantification be an imaging biomarker for cardiac amyloidosis?Japanese journal of radiology · 2022Article
- Quantitative susceptibility mapping of the head-and-neck using SMURF fat-water imaging with chemical shift and relaxation rate corrections.Magnetic resonance in medicine · 2022Article
- Magnetic susceptibility and R2* of myocardial reperfusion injury at 3T and 7T.Magnetic resonance in medicine · 2022Article
- Feasibility of QSM in the human placenta.Magnetic resonance in medicine · 2021Article
- Iron imaging in myocardial infarction reperfusion injury.Nature communications · 2020Article
- Automated adaptive preconditioner for quantitative susceptibility mapping.Magnetic resonance in medicine · 2020Article
- Free breathing three-dimensional cardiac quantitative susceptibility mapping for differential cardiac chamber blood oxygenation - initial validation in patients with cardiovascular disease inclusive of direct comparison to invasive catheterization.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 2 institutions in 1 country.
Funding
Abstract
purposeTo demonstrate the feasibility of in vivo quantitative susceptibility mapping (QSM) in cardiac MRI and to show that mixed-venous oxygen saturation (SvO
methodsElectrocardiographic-gated multi-echo 2D gradient echo data were collected at 1.5 T from 14 healthy volunteers during successive breath-holds. Phase wraps and fat chemical shift were removed using a graph-cut-based phase analysis and IDEAL in an iterative approach. The large susceptibility range from air in the lungs to blood in the heart was addressed by using the preconditioning approach in the dipole field inversion. SvO
resultsNine out of fourteen volunteers (64%) yielded interpretable cardiac QSM. QSM maps showed strong differential contrast between RV and LV blood with RV blood having higher susceptibility values (291.5 ± 32.4 ppb), which correspond to 78.3 ± 2.3% SvO
conclusionIn vivo cardiac QSM is feasible and can be used to measure SvO
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.