Evidence map›Paper›PMID 28651585›Full record

ArticleBiomedical engineering online2017

A vessel length-based method to compute coronary fractional flow reserve from optical coherence tomography images.

Kyung Eun Lee, Seo Ho Lee, Eun-Seok Shin, Eun Bo Shim

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 24 citations in OpenAlex.

  1. Pooled it
  2. Diagnostic accuracy of optical flow ratio: an individual patient-data meta-analysis.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2023
    Pooled it
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Kyung Eun LeeDepartment of Mechanical and Biomedical Engineering, Kangwon National University, Kangwondaehak-gil, Chuncheon-si, Kangwon-do, 200-701, Republic of Korea.
Seo Ho LeeDepartment of Mechanical and Biomedical Engineering, Kangwon National University, Kangwondaehak-gil, Chuncheon-si, Kangwon-do, 200-701, Republic of Korea.
Eun-Seok ShinDepartment of Cardiology, University of Ulsan College of Medicine, Ulsan, South Korea.
Eun Bo ShimDepartment of Mechanical and Biomedical Engineering, Kangwon National University, Kangwondaehak-gil, Chuncheon-si, Kangwon-do, 200-701, Republic of Korea. ebshim@kangwon.ac.kr.
Kangwon National University · KRUniversity of Ulsan · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHemodynamic simulation for quantifying fractional flow reserve (FFR) is often performed in a patient-specific geometry of coronary arteries reconstructed from the images from various imaging modalities. Because optical coherence tomography (OCT) images can provide more precise vascular lumen geometry, regardless of stenotic severity, hemodynamic simulation based on OCT images may be effective. The aim of this study is to perform OCT-FFR simulations by coupling a 3D CFD model from geometrically correct OCT images with a LPM based on vessel lengths extracted from CAG data with clinical validations for the present method.

methodsTo simulate coronary hemodynamics, we developed a fast and accurate method that combined a computational fluid dynamics (CFD) model of an OCT-based region of interest (ROI) with a lumped parameter model (LPM) of the coronary microvasculature and veins. Here, the LPM was based on vessel lengths extracted from coronary X-ray angiography (CAG) images. Based on a vessel length-based approach, we describe a theoretical formulation for the total resistance of the LPM from a three-dimensional (3D) CFD model of the ROI.

resultsTo show the utility of this method, we present calculated examples of FFR from OCT images. To validate the OCT-based FFR calculation (OCT-FFR) clinically, we compared the computed OCT-FFR values for 17 vessels of 13 patients with clinically measured FFR (M-FFR) values.

conclusionA novel formulation for the total resistance of LPM is introduced to accurately simulate a 3D CFD model of the ROI. The simulated FFR values compared well with clinically measured ones, showing the accuracy of the method. Moreover, the present method is fast in terms of computational time, enabling clinicians to provide solutions handled within the hospital.

Indexed as

Fractional Flow Reserve, MyocardialTomography, Optical CoherenceComputer SimulationCoronary VesselsFemaleHumansMaleMiddle AgedComputer simulationFractional flow reserveOptical coherence tomographyVessel length-based method

Identifiers

PMID28651585
PMCPMC5485716
OpenAlexW2683088556

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.