ArticleProceedings of SPIE--the International Society for Optical Engineering2017
Initial Simulated FFR Investigation Using Flow Measurements in Patient-specific 3D Printed Coronary Phantoms.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03149042 (Validation of a Computed Tomography), which is not on this map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Validation of a Computed Tomography (CT) Based Fractional Flow Reserve (FFR) Software Using the 320 Detector Aquilion ONE CT Scanner.
Who cites it
9 citing papers in PubMed.
- Decoding triple negative breast cancer bone metastasis: from 3D bioprinted models to clinical translation.Journal of nanobiotechnology · 2026Review
- Use of patient specific 3D printed neurovascular phantoms to simulate mechanical thrombectomy.3D printing in medicine · 2021Article
- Challenges in hemodynamics assessment in complex neurovascular geometries using computational fluid dynamics and benchtop flow simulation in 3D printed patient specific phantoms.Proceedings of SPIE--the International Society for Optical Engineering · 2021Article
- Design, Implementation, and Validation of a Pulsatile Heart Phantom Pump.Journal of digital imaging · 2020Article
- Clinical situations for which 3D printing is considered an appropriate representation or extension of data contained in a medical imaging examination: adult cardiac conditions.3D printing in medicine · 2020Article
- Method to simulate distal flow resistance in coronary arteries in 3D printed patient specific coronary models.3D printing in medicine · 2020Article
- Initial evaluation of three-dimensionally printed patient-specific coronary phantoms for CT-FFR software validation.Journal of medical imaging (Bellingham, Wash.) · 2019Article
- 3D Printed Cardiovascular Patient Specific Phantoms Used for Clinical Validation of a CT-derived FFR Diagnostic Software.Proceedings of SPIE--the International Society for Optical Engineering · 2018Article
- Design and fabrication of a 3D-printed oral stent for head and neck radiotherapy from routine diagnostic imaging.3D printing in medicine · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
purposeAccurate patient-specific phantoms for device testing or endovascular treatment planning can be 3D printed. We expand the applicability of this approach for cardiovascular disease, in particular, for CT-geometry derived benchtop measurements of Fractional Flow Reserve, the reference standard for determination of significant individual coronary artery atherosclerotic lesions. MATERIALS AND
methodsCoronary CT Angiography (CTA) images during a single heartbeat were acquired with a 320×0.5mm detector row scanner (Toshiba Aquilion ONE). These coronary CTA images were used to create 4 patient-specific cardiovascular models with various grades of stenosis: severe, <75% (n=1); moderate, 50-70% (n=1); and mild, <50% (n=2). DICOM volumetric images were segmented using a 3D workstation (Vitrea, Vital Images); the output was used to generate STL files (using AutoDesk Meshmixer), and further processed to create 3D printable geometries for flow experiments. Multi-material printed models (Stratasys Connex3) were connected to a programmable pulsatile pump, and the pressure was measured proximal and distal to the stenosis using pressure transducers. Compliance chambers were used before and after the model to modulate the pressure wave. A flow sensor was used to ensure flow rates within physiological reported values.
results3D model based FFR measurements correlated well with stenosis severity. FFR measurements for each stenosis grade were: 0.8 severe, 0.7 moderate and 0.88 mild.
conclusions3D printed models of patient-specific coronary arteries allows for accurate benchtop diagnosis of FFR. This approach can be used as a future diagnostic tool or for testing CT image-based FFR methods.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.